摘要
从斜窄流分级机工况出发 ,分析了分级单元堵塞的根源是矩形断面结构尺寸不合理 。
Through the analysis of the working conditions of inclined narrow flow classifier tank,the cause of the blockage of classifying unit is found to be the irrationality of the structural dimensions of rectangular section.Theoretical calculation of suitable coefficient value of shape and dimensions of the rectangular section of classifying unit was made.
出处
《金属矿山》
CAS
北大核心
2003年第11期32-35,共4页
Metal Mine
关键词
斜窄流分级机
分级单元浅槽
水力坡降
KMLF型
尺寸计算
断面结构
Inclined narrow flow classifying tank,Shallow trough of classifying unit,Hydraulic gradient,Coefficient of section shape and size