涂层支架的研究进展
被引量:2
Review of eluting stent
摘要
经皮冠状动脉内气囊血管成形术后常产生支架内再狭窄的问题 ,目前采用不同涂层技术研制各种涂层支架以对抗支架内再狭窄。
出处
《浙江大学学报(医学版)》
CAS
CSCD
2003年第5期453-457,共5页
Journal of Zhejiang University(Medical Sciences)
参考文献23
-
1HEUBLEIN B, OZBEK C, PETHIG K. Silicon carbide-coated stents: clinical experience in coronary lesions with increased thrombotic risk[J]. J Endovasc Surg, 1998,5(1):32--36.
-
2FOURNIER J, CALABUIG J, MERCHAN A, et al.Initial results and 6 month clinical follow-up after implantation of a silicon carbide coated coronary stent[J].Rev Esp Cardiol, 2001,54(5) :567--572.
-
3ANTONIUCCI D, VALENTI R, MIGLIORINI A, et al. Clinical and angiographic outcomes following elective implantation of the Carhostent in patients at high risk of restenosis and target vessel failure [J].Catheter Cardiovasc Interv, 2001,54(4) :420--426.
-
4KEDEV S, GUAGLIUMI G, VALSECHI O, et al.Heparin-coated versus uncoated Palmaz-Schatz stent in native coronary circulation. A randomized study with blind angioscopic assessment[J].Int J Artif Organs,2002,25(5):461--469.
-
5NELSON S R, de SOUZA N M, ALLISON D J. Endovascular stents and stent-grafts: is heparin coating desirable[J]. Carfliovasc Intervent Rafliol, 2000, 23(4):252--255.
-
6CRUZ D, KARLSBERG R, TAKANO Y, et al. Subacute stent thrombosis associated with a heparin-coatedstent and heparin-induced thromhocytopenia[J].Catheter Carfliovase Interv, 2003,58 (1) : 80-- 83.
-
7SOUSA J E, COSTA M A, ABIZAID A, et al. Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: A quantitative coronary angiography and three-dimensional intravascular ultrasound study[J]. Circulation,2001,103(2) : 192-195.
-
8MORICE M C, SERRUYS P W, SOUSA J E, et al.RAVEL Study Group. A randomized comparison of asirolimus-eluting stent with a standard stent for coronary revascularization[J]. N Engl J Med, 2002,346(23) : 1773-- 1780.
-
9HELDMAN A W, CHENG L, JENKINS G M, et al.Paclitaxel stent coating inhibits neointimal hyperplasia at 4 weeks in a porcine model of coronary restenosis[J]. Circulation, 2001,103(18) :2289--2295.
-
10GRUBE E, SILBER S, HAUPTMANN K E, et al.TAXUS I: six- and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions [J]. Circulation, 2003,107 (1):38-- 42.
同被引文献37
-
1ROGERS D K.Drug-Eluting Stents: Role of stent design, delivery vehicle,and drug selection intravascular stent[J].Reviews in Cardiovascular Medicine, 2002, 3( 5): s10-s15.
-
2BALCON R, BEYAR R, CHIERCHIA S.Recommendations on stent manufacture, implantation and utilization[J].European Heart Journal, 1997, 18: 1536-1547.
-
3RAVAL A, CHOUBEY A, KOTHWALA D.Development and assessment of 316 LVM cardiovascular stents[J].Materials Science and Engineering A, 2004, 386: 331-343.
-
4THIERRYA B, MERHIB Y, BILODEAUB L, et al.Nitinol versus stainless steel stents: acute thrombogenicity study in an ex vivo porcine model[J].Biomaterials, 2002, 23:2997–3005.
-
5KATHURIA Y P.An overview on laser microfabrication of biocompatible metallic stent for medical therapy[J].Proceedings of SPIE,2004, 5399: 234-244.
-
6HAASE J, HOFMANN M, SCHOPF J.Long- term outcome after implantation of bare metal stents for the treatment of coronary artery disease[J].Journal of Interventional Cardiology, 2003, 16(6):469-473.
-
7SANTIN M, MIKHALOVAKA L, LLIYD A W.In vitro host response assessment of biomaterials for cardiovascular stent manufacture[J].Journal of Materials Science: Materials in Medicine, 2004,15: 473-477.
-
8STOECKEL D, BONSIGNORE C,DUDA S.A survey of stent designs[J].Min Invas Ther & Allied Technol, 2002,11(4):137–147.
-
9GACHON C, DELASSUS P.Accuracy of laser-cutting and its influence on the mechanical behaviour of stents[J].Proceedings of SPIE, 2003, 4876: 574-581.
-
10MCCLEAN D R, EIGLER N L.Stent design: Implications for restenosis[J].Reviews in Cardiovascular Medicine, 2002, 3( 5): s16-s22.
引证文献2
-
1周永恒,廖健宏,蒙红云,曾常春,刘颂豪.血管内支架分类与技术进展[J].华南师范大学学报(自然科学版),2005,37(2):136-142. 被引量:5
-
2周永恒,蒙红云,曾常春,廖健宏.血管内支架的技术与性能[J].生物医学工程学杂志,2007,24(6):1423-1427. 被引量:10
二级引证文献14
-
1王建宇,李佳戈,刘丽,王硕,汤京龙,陆颂芳.镍钛合金颈动脉支架的长期加速腐蚀疲劳测试[J].北京生物医学工程,2007,26(1):78-80. 被引量:3
-
2杨治军,周廉,李争显,于振涛,罗丽娟,蔡玉荣.医用316L不锈钢表面沉积Fe/Pt和Pt/Fe/Pt磁性薄膜的研究[J].稀有金属材料与工程,2007,36(11):1960-1963. 被引量:3
-
3章娜,贾健雄,冯晓明,奚廷斐,周红娇.药物支架的研究进展[J].药物分析杂志,2008,28(5):817-823. 被引量:2
-
4张会君.从血管支架材料学分类认识颅内外动脉支架置入后的生物相容性反应[J].中国组织工程研究与临床康复,2008,12(22):4311-4314. 被引量:3
-
5肖勇,文喜陵.血管管腔内支架的技术性能及临床应用[J].中国组织工程研究与临床康复,2008,12(30):5939-5941. 被引量:5
-
6夏永辉,徐克,冯博,齐民,黄莹莹.外周动脉支架聚丙交酯乙交酯涂层的制备及其性能研究[J].介入放射学杂志,2009,18(4):290-293. 被引量:4
-
7胡静君.颅脑支架在颅脑损伤中的应用及其并发症:优劣分析[J].中国组织工程研究与临床康复,2009,13(43):8548-8551. 被引量:3
-
8庞瑜,张国浩,程丑夫.涂层材料及技术在医学临床领域的应用[J].中国组织工程研究与临床康复,2011,15(34):6403-6406. 被引量:1
-
9杨洋,闻炳基,袁玮.p53变异在结肠癌原发灶和肝转移灶的配对比较及其与术后生存的关系[J].癌症,2000,19(5):409-411. 被引量:2
-
10劳永华,张文威,徐笑凡,李卫荣,黄岳山.AZ31镁合金在人工血浆中的动态降解行为[J].稀有金属材料与工程,2014,43(5):1242-1245. 被引量:2
-
1易忠群,徐仲逊.聚合人血清白蛋白受体试剂研制与临床应用[J].西北国防医学杂志,1990,11(3):22-24.
-
2陈勇.纳米激光热电探头[J].发明与创新(大科技),2005(4):46-46.
-
3周红梅,杨国山,谢向东,蔡反攻,薛永库.数字式诊断X射线机的高压测试仪[J].核电子学与探测技术,2002,22(6):554-556. 被引量:1
-
4王礼林.陆地型伤员搜索仪的研制[J].医疗卫生装备,1996,17(4):11-13.
-
5吴志强,韩力军,沈力平,袁修干,李潭秋.水升华器用多孔板的物理特性研究[J].航天医学与医学工程,2001,14(2):127-131. 被引量:3
-
6查选平,杜芳,高建华,李世恒,姜平,刘四方,连云峰.应用计算机测量乳房基本尺寸的实验研究[J].中华整形外科杂志,2005,21(3):178-180. 被引量:6
-
7查选平,杜芳,高建华,李世恒,姜平,刘四方,连云峰.乳房三维形貌非接触性测量系统的研制[J].第一军医大学学报,2005,25(3):262-266. 被引量:4
-
8外军消息[J].海军医学杂志,1996,0(3):289-289.
-
9王常有,于瑞敏.《部队防疫保障模块》系统的设计与构建[J].解放军预防医学杂志,2004,22(4):317-319. 被引量:1
-
10孙海龙,张清,范国英,赵睿,李浩,马静,曹务春.部队防疫防护保障支持系统的建立[J].解放军预防医学杂志,2005,23(2):96-98. 被引量:5