期刊文献+

涂层支架的研究进展 被引量:2

Review of eluting stent
下载PDF
导出
摘要 经皮冠状动脉内气囊血管成形术后常产生支架内再狭窄的问题 ,目前采用不同涂层技术研制各种涂层支架以对抗支架内再狭窄。
出处 《浙江大学学报(医学版)》 CAS CSCD 2003年第5期453-457,共5页 Journal of Zhejiang University(Medical Sciences)
  • 相关文献

参考文献23

  • 1HEUBLEIN B, OZBEK C, PETHIG K. Silicon carbide-coated stents: clinical experience in coronary lesions with increased thrombotic risk[J]. J Endovasc Surg, 1998,5(1):32--36.
  • 2FOURNIER J, CALABUIG J, MERCHAN A, et al.Initial results and 6 month clinical follow-up after implantation of a silicon carbide coated coronary stent[J].Rev Esp Cardiol, 2001,54(5) :567--572.
  • 3ANTONIUCCI D, VALENTI R, MIGLIORINI A, et al. Clinical and angiographic outcomes following elective implantation of the Carhostent in patients at high risk of restenosis and target vessel failure [J].Catheter Cardiovasc Interv, 2001,54(4) :420--426.
  • 4KEDEV S, GUAGLIUMI G, VALSECHI O, et al.Heparin-coated versus uncoated Palmaz-Schatz stent in native coronary circulation. A randomized study with blind angioscopic assessment[J].Int J Artif Organs,2002,25(5):461--469.
  • 5NELSON S R, de SOUZA N M, ALLISON D J. Endovascular stents and stent-grafts: is heparin coating desirable[J]. Carfliovasc Intervent Rafliol, 2000, 23(4):252--255.
  • 6CRUZ D, KARLSBERG R, TAKANO Y, et al. Subacute stent thrombosis associated with a heparin-coatedstent and heparin-induced thromhocytopenia[J].Catheter Carfliovase Interv, 2003,58 (1) : 80-- 83.
  • 7SOUSA J E, COSTA M A, ABIZAID A, et al. Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: A quantitative coronary angiography and three-dimensional intravascular ultrasound study[J]. Circulation,2001,103(2) : 192-195.
  • 8MORICE M C, SERRUYS P W, SOUSA J E, et al.RAVEL Study Group. A randomized comparison of asirolimus-eluting stent with a standard stent for coronary revascularization[J]. N Engl J Med, 2002,346(23) : 1773-- 1780.
  • 9HELDMAN A W, CHENG L, JENKINS G M, et al.Paclitaxel stent coating inhibits neointimal hyperplasia at 4 weeks in a porcine model of coronary restenosis[J]. Circulation, 2001,103(18) :2289--2295.
  • 10GRUBE E, SILBER S, HAUPTMANN K E, et al.TAXUS I: six- and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions [J]. Circulation, 2003,107 (1):38-- 42.

同被引文献37

  • 1ROGERS D K.Drug-Eluting Stents: Role of stent design, delivery vehicle,and drug selection intravascular stent[J].Reviews in Cardiovascular Medicine, 2002, 3( 5): s10-s15.
  • 2BALCON R, BEYAR R, CHIERCHIA S.Recommendations on stent manufacture, implantation and utilization[J].European Heart Journal, 1997, 18: 1536-1547.
  • 3RAVAL A, CHOUBEY A, KOTHWALA D.Development and assessment of 316 LVM cardiovascular stents[J].Materials Science and Engineering A, 2004, 386: 331-343.
  • 4THIERRYA B, MERHIB Y, BILODEAUB L, et al.Nitinol versus stainless steel stents: acute thrombogenicity study in an ex vivo porcine model[J].Biomaterials, 2002, 23:2997–3005.
  • 5KATHURIA Y P.An overview on laser microfabrication of biocompatible metallic stent for medical therapy[J].Proceedings of SPIE,2004, 5399: 234-244.
  • 6HAASE J, HOFMANN M, SCHOPF J.Long- term outcome after implantation of bare metal stents for the treatment of coronary artery disease[J].Journal of Interventional Cardiology, 2003, 16(6):469-473.
  • 7SANTIN M, MIKHALOVAKA L, LLIYD A W.In vitro host response assessment of biomaterials for cardiovascular stent manufacture[J].Journal of Materials Science: Materials in Medicine, 2004,15: 473-477.
  • 8STOECKEL D, BONSIGNORE C,DUDA S.A survey of stent designs[J].Min Invas Ther & Allied Technol, 2002,11(4):137–147.
  • 9GACHON C, DELASSUS P.Accuracy of laser-cutting and its influence on the mechanical behaviour of stents[J].Proceedings of SPIE, 2003, 4876: 574-581.
  • 10MCCLEAN D R, EIGLER N L.Stent design: Implications for restenosis[J].Reviews in Cardiovascular Medicine, 2002, 3( 5): s16-s22.

引证文献2

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部