期刊文献+

Influence of Manufacturing Process of Warp-knitted Vascular Prosthesis on the Wall Homogeneity 被引量:1

Influence of Manufacturing Process of Warp-knitted Vascular Prosthesis on the Wall Homogeneity
下载PDF
导出
摘要 This paper reports the evolution of textile structure and mechanical properties of vascular prosthesis in the level of the whole prosthesis and the constituent filaments with respect to the manufacturing process. The tubular wall of the prosthesis is divided circumferentially into three zones; basic line (BL), remeshing line ( RL) and guide line ( GL). Some heterogeneity has been observed on the tubular wall in terms of stitch structure of the prosthesis and linear density of the constituent filaments. The breaking position of the prosthesis under circumferential tensile localizes preferentially in remeshing line that is the weakest zone by warp knitting with double needle bed. Furthermore, the statistical differences of the mechanical properties of the filaments of zone RL, GL and BL have been confirmed too. It is predictable that the deterioration of prosthesis, under physiological loads (periodical pulse blood pressure etc.), could happen firstly in the weaker zone in vivo. This paper reports the evolution of textile structure and mechanical properties of vascular prosthesis in the level of the whole prosthesis and the constituent filaments with respect to the manufacturing process.The tubular wall of the prosthesis is divided circumferentially into three zones: basic line (BL),remeshing line (RL) and guide line (GL). Some heterogeneity has been observed on the tubular wall in :erms of stitch structure of the prosthesis and linear density of the constituent filaments. The breaking position of the prosthesis under circumferential tensile localizes preferentially in remeshing line that is the weakest zone by warp knitting with double needle bed. Furthermore, the statistical differences of the mechanical properties of the filaments of zone RL, GL and BL have been confirmed too. It is predictable that the deterioration of prosthesis, under physiological loads (periodical pulse blood pressure etc.), could happen firstly in the weaker zone in vivo.
作者 王璐 丁辛
出处 《Journal of Donghua University(English Edition)》 EI CAS 2003年第2期9-13,共5页 东华大学学报(英文版)
基金 Funded by the Shanghai Post Doctoral Foundation Overseas Returned Scholars' Foundation of Education Ministry the Shanghai Key Discipline Project
关键词 Vascular prosthesis Warp-knitted structure Circumferential tensile properties Manufacturing process 纺织品 机械性质 修复 制造工艺 经纱织结构
  • 相关文献

参考文献10

  • 1Wang L.Study of ageing of textile vascular prostheses[]..2001
  • 2Jin Pihuan.Statistics Methods for Medicine[]..1992
  • 3Pourdeyhimi B,Wagner D. J.Biomed[].Materials Research Bulletin.1986
  • 4ISO.Cardiovascular implants-tubular vascular prostheses[].ISO:.1998
  • 5Guidoin R,King M,Marceau D,et al,J.Biomed[].MaterRes.1987
  • 6Nunn,DB,Freeman,MH,Hudgins,MS.Postoperative alterations in size of aortic Dacron grafts[].Annals of Surgery.1979
  • 7Berger J H,Sauvage LR.Late fiber deterioration in Dacron arterialgrafts[].Annals of Surgery.1981
  • 8Guidion R,Chakfe N.Aneurysmal deterioration of arterial substitutes[].In: Current Therapy in Vascular Surgery Ernst C B Stanley J C(eds)B C Decker Ed Toronto Philadelphia.1990
  • 9Riepe G,Lees J H,Schrder et al.Long-term in-vivo alterations of polyester vascular grafts in human[]..1997
  • 10Chakfe N,Riepe G,Dieval F,et al. Journal of Vascular Surgery . 2001

同被引文献45

  • 1R. Uflacker,Jacob Robison.Endovascular treatment of abdominal aortic aneurysms: a review[J]. European Radiology . 2001 (5)
  • 2Dr. J. C. Parodi MD,J. C. Palmaz MD,H. D. Barone PhD.Transfemoral intraluminal graft implantation for abdominal aortic aneurysms[J]. Annals of Vascular Surgery . 1991 (6)
  • 3Dr. Robert G. Guidoin,Martin King,Michel Marois,Louisette Martin,Daniel Marceau,Robin Hood,Roshan Maini.New polyester arterial prostheses from great britain: anin vitro andin vivo evaluation[J]. Annals of Biomedical Engineering . 1986 (4)
  • 4Kipshidze N,,Sahota H,Bakhutashvili I.Experi mental and Clinical Development of Aortic Stent-Grafts and Review of Contemporary Types of Sevices [ M]. Stent-Graft Update . 2000
  • 5For michi M,,Marois Y,Roby P,et al.Endovascular Repair of Thoracic Aortic Aneurys min Dogs :Evaluation of a Nitinol-Polyester Self-expanding Stent-Graft. Journal of Endovascular Therapy . 2000
  • 6Guidoin R,Peirano M,Barone H D,et al.Transrenal Deployment of a Modular Stent-Graft to Repair AAAs with Short and/or Angulated Necks :Experi ments in Dogs. Artificial Cells,Blood Substitutes,and I mmobilization Biotechnology . 2008
  • 7Guidoin R,Peirano M,Barone H B,et al.Analysis of Explanted Latecba Modular Stent-Grafts Deploy Trans- renally to Repair AAAs with Short Necks in29Dogs. Artificial Cells,Blood Substitutes,and I mmobilization Biotechnology . 2008
  • 8Malina M,Lindblad B,Ivancev K,et al.Endovascular AAA Exclusion:Will Stents with Hooks and Barbs Prevent Stent-Graft Migration-[ J ]. Journal of Endovascular Surgery . 1998
  • 9Resch T,Malina M,Lindblad B,et al.The I mpact of Stent-graft Development on Outcome of AAA Repair :a7 Year Experience. European Journal of Vascular and Endovascular Surgery . 2001
  • 10Major A,Guidoin R,Soulez G,et al.I mplant Degradation and Poor Healing after Endovascular Repair of Abdominal Aortic Aneurys ms :an Analysis of Explanted Stent-Grafts. Journal of Endovascular Therapy . 2006

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部