期刊文献+

生物除铁除锰水厂的工艺设计与运行效果 被引量:20

Technical Design and Performance of Waterworks for Iron and Manganese Removal by Microorganism
下载PDF
导出
摘要 在生物除铁除锰技术指导下设计建造的沈阳经济技术开发区供水厂 ,是我国第一座成规模的典型的地下水生物除铁除锰水厂。它的工艺特点体现在跌水弱曝气 ,在同一生物滤层中除铁除锰及培养期、稳定期的反冲洗机制。生物滤层培养成熟后 ,滤池铁锰去除效率达 99%以上 ,出水水质优于国家标准 ,取得了稳定的运行效果。 Shenyang economic development zone waterworks is the first large-scale biological underground water Fe/Mn removal facility in this country. By adopted cascade weak aeration all the functions related to Fe/Mn removal such as the microorganism culturing and maturing, steady filtering and backwashing are processed in the same filtering bed. When the microorganism maturing, a steady state stable Fe/Mn removal ratio excess 99% has been obtained, which is better than the requirement of the national standard.
出处 《给水排水》 CSCD 北大核心 2003年第11期26-28,共3页 Water & Wastewater Engineering
基金 "九五"国家科技攻关课题 (96 - 90 9- 0 1 - 0 2 - 0 4 )
  • 相关文献

参考文献4

  • 1张杰,杨宏,徐爱军,鲍志戎,李惟.生物固锰除锰技术的确立[J].给水排水,1996,22(11):5-10. 被引量:97
  • 2张杰,戴镇生.地下水除铁除锰现代观[J].给水排水,1996,22(10):13-16. 被引量:74
  • 3中国市政工程东北设计研究院.生物除铁除锰成套技术研究[M].长春:中国市政工程东北设计研究院,2001..
  • 4J Vandenabeele, D Debeer, et al. Influence of nitrate on manganese removing microbial consortia from sand filter. Wat Res, 1995, 29(2) :579--587.

二级参考文献3

  • 1J. Vandenabeele,D. Beer,R. Germonpré,W. Verstraete. Manganese oxidation by microbial consortia from sand filters[J] 1992,Microbial Ecology(1):91~108
  • 2范懋功.地下水接触氧化除锰中催化剂的形态[J]中国给水排水,1985(03).
  • 3李圭白.地下水除铁技术的若干新发展[J]建筑技术通讯(给水排水),1983(03).

共引文献134

同被引文献143

引证文献20

二级引证文献97