摘要
抽头是屏蔽电缆泄漏最严重的部分.利用传输线理论和广义二端口网络法提出了求解包含抽头线的多导体传输线串扰的分析方法,计算出不同抽头长度和屏蔽层的不同接地方式下耦合到屏蔽芯线上的电压和电流,最后从理论上分析了产生这种结果的原因,并提出减小这种耦合的方法.
The leakage of the pigtail section of a shielded cable is the most serious. In this paper, an analytical technique for multiconductor transmission lines crosstalk is presented by using the transmission line theory and the generalized twoport network method. Then the corresponding voltages and currents coupling to shielded wires are obtained with differentlength pigtails and different shieldgrounding configurations. Finally, the reason for producing this effect is discussed theoretically and a means of reducing the coupling is proposed.
出处
《西安电子科技大学学报》
EI
CAS
CSCD
北大核心
2003年第6期734-738,共5页
Journal of Xidian University
基金
国家部委科技重点实验室基金资助项目(99JS25 5 1)