期刊文献+

ICP-MS法测定PVC-U饮水管材(件)中的痕量铅、镉、锡、汞 被引量:5

DETERMINATION OF THE TRACE Pb,Cd, Sn AND Hg IN THE RIGID POLYVENYL CHLORIDE PIPES FOR DRINKING WATER SUPPLY BY ICP-MS
下载PDF
导出
摘要 采用电感耦合等离子体质谱(TCP-MS)法测定硬聚氯乙烯(PVC-U)饮水管材(件)中的痕量铅、镉、锡、汞,对影响测量结果的因素进行了分析。利用该法测定铅、镉、锡、汞的检出限分别为0.0028、0.0025、0.0052、0.0033μg/L,回收率为84.60%~94.30%,测定结果的相对标准偏差小于4.23%。 The trace Pb, Cd, Sn and Hg in the rigid polyvinyl chloride pipes ior drinking water supply were determined by inductively coupled plasma-mass spectrometry( ICP-MS). The detection limits of the method were 0.0028ug/L (Pb),0.0025μg/L(Cd),0.005 2μg/L( Sn) , 0.003 3μg/L(Hg). The recovery was 84.60%-94.30% . RSD was less than 4. 23% .
出处 《化学分析计量》 CAS 2003年第6期26-28,共3页 Chemical Analysis And Meterage
关键词 ICP-MS法 测定 PVC-U饮水管材 痕量元素 硬聚氯乙烯 电感耦合等离子体质谱法 ICP-MS, rigid polyvinyl chloride, pipe for drinking water supply, Pb, Cd, Sn, Hg, determination
  • 相关文献

参考文献6

  • 1.GB 9644—88.硬聚氯乙烯(PVC-U)饮水管材和管件铅、锡、镉、汞的萃取方法及允许值[S].,..
  • 2.GB 5750—85.生活饮用水卫生标准检验方法[S].,..
  • 3汗尔康.21世纪的分析化学[M].北京:科学出版社,1998.28.
  • 4Juvonen R, Lakomaa T. Determination of gold and the platinum group elements in geological samples by 1CP-MS after nickel sulphide fire assay: difficulties encountered with different types of geological samples. Talanta,2002,58 ( 3 ) :595.
  • 5El Himri M, Pastor A, M de la Guardia. Determination of uranium in tap water by 1CP-MS. Anal Bioanal Chem,2000,367(2) : 151.
  • 6USA EPA method 200.8 Determination of trace elements in waters and water by inductively coupled plasma-mass spectromtry.