VRDS装置常压分馏塔系统的问题分析

Problem Analysis of the Atmospheric Tower System of VRDS Unit
下载PDF
导出
摘要 胜利炼油厂重油加氢 (VRDS)装置的常压分馏塔为填料塔 ,2 0 0 1年检修开工后该系统出现异常 ,经过查找分析 ,确定轻烃 The atmospheric tower of VRDS unit is a packing column. After its startup after the overhaul in 2001, this system was abnormal .Through the checking and analysis, it was found out that the inner leakage of light hydrocarbons/product vacuum residual oil heat exchanger and the reboiler of diesel oil stripper is the main reasons for the abnormal operation of the plant.
作者 王昌岭
出处 《齐鲁石油化工》 2003年第3期215-218,共4页 Qilu Petrochemical Technology
关键词 常压分馏塔 填料段 柴油抽出 换热器泄漏 过汽化油 atmospheric tower, packing section, diesel oil draw out, exchanger leakage, over flash oil