期刊文献+

发电机内冷水处理方法的研究及探讨 被引量:2

Research and Discussion on Method for Inner Generator Cooling Water Treatment
下载PDF
导出
摘要 湖南石门电厂发电机内冷水处理先后采用了四种不同方法,即BTA+EA缓蚀剂法、溢流法、小混床处理法、除盐水与凝结水联合处理法。前三种处理方法均存在不同程度的水质超标,结合多年现场运行经验和不断探讨,针对存在的问题,提出了新的处理方法,并加以实施。实践证明,该方法对防止发电机内冷水系统空芯铜导线的腐蚀有明显效果,为发电机的安全经济运行提供了保障。 Four treatment methods have carried out on generator inner cooling water of Hunan Shimen power Plant,namely BTA+EA,overflowing,small mixed bed and combined treatment of desalt water with condensed water. The quality of water treated with the former three methods is out of standard to some extent.Combined with many years experience and study comtinuously,the author put up with new treatment method and put to use. This method is very effect to protect inner cooling water system's copper tube lead of generator from corrosion,and safeguards generator's economic work.
出处 《四川电力技术》 2003年第6期20-22,共3页 Sichuan Electric Power Technology
关键词 发电机 内冷水 防腐处理 效果 generator inner coolling water anticorrosion effect