期刊文献+

石英谐振传感器液相稳定平台构建及检测HCMV的实验研究 被引量:2

Design of a stable system of quartz oscillation sensor in liquid phase and the test of HCMV
下载PDF
导出
摘要 目的 建立石英谐振压电基因传感器检测系统液相稳定平台并应用该检测系统实时检测链置换扩增(Stranddisplacement amplification,SDA)反应。方法①观察以金属夹具式和粘胶式两种检测池连接方式构成的传感器在液相中的频率稳定性;②以巨细胞病毒(Human cytomegalovirus,HCMV)为检测对象,建立SDA反应系统;③传感器检测系统对HCMVSDA反应进行实时检测。结果①新型金属夹具式可调节及可换式传感器检测池可实现传感器在液相中的频率稳定性;②SDA反应可引起压电基因传感器的频率持续下降;③在一定范围内核酸杂交所引起的频率下降幅度随加入的靶序列浓度提高而增大。结论 成功构建压电基因传感器液相检测稳定平台并实现对SDA反应的实时检测;该系统可直接检测基因组DNA并可广泛应用于病原微生物的临床检测。 Objective To design the stable system of piezoelectric gene sensor in liquid phase and detect strand displacement amplification(SDA) reaction with the piezoelectric gene sensor. Methods The frequency stability of pools with metal clamping and glue connecting way in liquid phase was observed. SDA reaction system was established using human cytomegalovirus( HCMV) as the detecting subject. Real time monitoring of HCMV SDA reaction was performed by using the piezoelectric gene sensor system. Results A new sensor-testing pool with the metal clamping of the adjustable and exchangeable style was able to solve the problem of the frequency stability in liquid phase. SDA could lead to continuous reduction of frequency in piezoelectric gene sensor. The degree of frequency reduction resulted from gene reaction was positively correlated with the consistency of the target gene in a certain range. Conclusion We have designed the system of piezoelectric gene sensor in liquid phase and conducted real time monitoring of the detection of SDA successfully. The system can be used for the direct detection of gene DNA as well as in the clinical detection of pathogenic microbes.
出处 《第三军医大学学报》 CAS CSCD 北大核心 2003年第21期1954-1957,共4页 Journal of Third Military Medical University
基金 国家"863"计划重大专项基金(2002AARZ2023) 国家"九五"科技攻关项目(96-A23-04-04) 国家自然科学基金资助项目(30270388) 全军"九五"课题(98MO94) 全军"十五"课题(01MA180 01LO65) 重庆市应用基础研究项目(2002-10-78) 重庆市科委风险投资基金(0499
关键词 压电基因传感器 稳定性 链置换扩增(SDA) 巨细胞病毒 piezoelectric gene sensor stability strand displacement amplification cytomegalovirus
  • 相关文献

参考文献8

  • 1张晨光.巨细胞病毒感染的实验室诊断和治疗现况[J].国外医学(流行病学.传染病学分册),1997,24(1):6-11. 被引量:9
  • 2蒋天伦,府伟灵,张波,陈鸣,刘明华,张雪,赵树铭,俞凡,陈小兵.链置换扩增(SDA)压电DNA传感器[J].第三军医大学学报,2002,24(1):26-28. 被引量:5
  • 3Tatsuma T, Watanabe Y, Oyama N, et al. Multichannel quartz crystal microbalance[ J I. Anal Chem, 1999,71 (17) : 3632 - 3636.
  • 4Ormrud D, Scott L J, Perry C M. Valaeielovir: a review of its long term utility in the management of genital herpes simplex virus and cytomegaloviyus infections[J]. Drugs, 2000,59(4):839-863.
  • 5Umek R M, Lin S W, Vielmetter J, et al. Electronic detection of nucleic acids: a versatile platform for molec ular diagnostics [ J ]. J Mol Diagn,2001, 3(2):74-84.
  • 6Towery R B, Fawcett N C, Zhang P, et al. Genomic DNA hybridizes with the same rate constant on the QCM biosensor as in homogeneous solution[J]. Biosens Bioelectron, 2002, 16(1-2) : 1 -8.
  • 7Martin S J, Frye G C. Characterization of a quartz crystal microbalance with simultaneous mass and liquid loading[J]. Anal Chem, 1991, 63(12) :2272- 2281.
  • 8Okahata Y, Kawase M, Nikura K, et al. Kinetic measurements of DNA hybridization on an oligonucleotide immobilized 27-MHz quartz crystal microbalance[J]. Anal Chem, 1995, 70(5) : 1255- 1296.

二级参考文献7

  • 1[1]Okahata Y, Niikura K. DNA sensor by using a quartz-crystal microbalance[J].Tanpakushitsu-Kakusan-Koso,1995,40(2): 165-172.
  • 2[2]Nicolini C, Erokhin V, Facci P, et al. Quartz balance DNA sensor[J].Biosens-Bioelectron,1997,12(7): 613-618.
  • 3[3]Janshoff A, Galla H J, Steinem C. Piezoelectric Mass-Sensing Devices asBiosensors-An Alternative to Optical Biosensors[J]. Angew Chem Int Ed Engl,2000,39(22):4 004-4 032.
  • 4[4]Spargo C A, Fraiser M S, Van Cleve M, et al. Detection of M. tuberculosis DNAusing thermophilic strand displacement amplification[J]. Mol Cell Probes,1996,10(4): 247-256.
  • 5[5]Wang J, Nielsen P E, Jiang M, et al. Mismatch-sensitive hybridizationdetection by peptide nucleic acids immobilized on a quartz crystal microbalance[J]. Anal Chem,1997,69(24):5 200-5 202.
  • 6[6]Okahata Y, Masunaga Y, Matsuno H, et al. Quantitative detection of a DNAligase reaction on a quartz-crystal microbalance[J]. Nucleic Acids Symp,1999,(42):147-148.
  • 7[7]Sauerbrey G. Use of vibrating quartz for thin film weighing and microweighing[J]. Z Phys,1959,155(2):206-209.

共引文献12

同被引文献19

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部