期刊文献+

BIOMECHANICAL STUDY ON UNILATERAL SINGLE-PLANE EXTERNAL FIXER 被引量:1

BIOMECHANICAL STUDY ONUNILATERAL SINGLE-PLANE EXTERNAL FIXER
下载PDF
导出
摘要 Six tibias removed from 30-40 years old males, who died in an accident for in less than 12 hours, were osteotomized at one-third supra-medium segment. They were fixed by an unilateral adjustable external fixer (UAEF), to be used as a model of external fixation of tibial fracture (MEFTF). The compression. tension, torsion, antero-posterior and lateral bending strength, and the strength for vertically extracting the pins from the tibia were determined in the MEFTF. Within a certain range of load, the correlation of strain to stress was basically a linear relationship. These data provide a theoretical basis of biomechanics for the improvement of UAEF and for early exercises of fracture patients, such as extend-bending of the joint.raising the limb and walking with a walking stick.
出处 《Chinese Medical Sciences Journal》 CAS CSCD 1995年第4期226-228,共3页 中国医学科学杂志(英文版)
关键词 TIBIA external fixator BIOMECHANICS 单侧外固定器 生物力学 骨折 功能锻炼 临床研究