摘要
讨论了标准GJB151B传导敏感度测试项目的测试要求,在传导敏感度测试时,施加在EUT电缆束、电源线上的传导干扰必须满足两条限值线之一,一条限值是校验设定值,另一条是加载于EUT电源线或电缆上的电流、电压或功率限值,测试中只需满足其中一条即可,但另一条限值不得超过标准的要求,只有这样才能使测试过程符合标准要求,正确评价EUT的抗干扰性能。
The requirment of conducted susceptibility testing conducted inteference must meet one of Limit Levels,one is testingsystem calibration data, the other one is current、voltage or power inflected on power line or cable of EUT, The output of testing system coincided with requirment of GJB151 B helped to evaluate anti-interference capability of EUT rightly.
出处
《微波学报》
CSCD
北大核心
2016年第S2期441-443,共3页
Journal of Microwaves