摘要
本文对低压配电系统谐波进行了相关的理论研究,对谐波治理方式、治理效果进行了现场测试和仿真计算研究,推荐出适用于地铁低压配电系统的治理方案,对今后地铁低压配电谐波治理具有重要参考价值。
In this paper,relevant theoretical research was conducted on the harmonic distortion of low voltage power supply system.Field test and simulation were taken to harmonic suppression methods and their effects.Finally,suitable harmonic suppression method for subway was recommended,which has important and referenced value to the harmonic restraint of low-voltage distribution system in the future.
出处
《电子测试》
2014年第8X期52-54,共3页
Electronic Test
关键词
地铁
低压配电系统
谐波
有源滤波装置
无功补偿
subway
Low voltage power supply system
harmonic
Active Power Filter
Reactive power compensation