摘要 面对广泛使用的新设备、新技术中存在的雷击概率,如何在广播电视高山台站的日常工作中做好机房及附属设备的防雷工作,更好地完成广播电视节目的发送任务,显得尤为重要。如何做好广播电视台特别是高山台站防雷减灾工作,是本文所要研究的中心主题,也是广东省信宜732台综合防雷系统技术改造工程的经验总结。 In the face of new equipment and new technology are widely used in the presence of lightning probability,how in the daily work of the radio and television of mountain stations do room and ancillary equipment lightning protection work,better to complete task of radio and television program delivery,is particularly important. How to do a good job in radio and television stations,especially for the lightning protection and mitigation of high mountain stations,is the central theme of this paper,but also the experience of 732 comprehensive lightning protection system in Xinyi,Guangdong province.