摘要
文章以两种故障类型为例,从X线机高压变压器次级线圈局部短路故障的表现以及分析检修两个角度对文章的主题进行了阐述。
In this paper,taking two kinds of fault types as an example,the paper describes the topic of the paper from two aspects:the performance of the local short circuit fault of the secondary coil of the X-ray machine and the analysis and maintenance.
出处
《电子测试》
2016年第10X期39-,45,共2页
Electronic Test
关键词
X线机
高压变压器
次级线圈
局部短路故障
分析检修
X-ray machine
high voltage transformer
secondary coil
local short circuit fault
analysis and repair