针对T3航站楼空调系统冷源侧的气象因素和能耗变化进行分析。首先,分析气象因素对能耗分布及变化的影响;其次通过单位产值综合能耗的对比,分析探索优化运控策略的措施。由于大型单体航站楼的负荷特点相似,对运控策略优化的措施在指导冷源测系统运行上具有一定的参考价值。
The meteorological factors and energy consumption of the cold source side of the air conditioning system of the T3 terminal building were analyzed.Firstly,the effects of meteorological factors on energy consumption distribution and change are analyzed,and then the measures of optimizing operation and control strategy are analyzed through the comparison of the comprehensive energy consumption of unit output value.As the load characteristics of large single terminal building is similar,this paper has some reference value to guide the operation of the cold source test system.
出处
《化工设计通讯》
CAS
2016年第10期107-,110,共2页
Chemical Engineering Design Communications
关键词
T3航站楼
冷源测
气象因素
能耗变化
运控策略
T3 terminal
cold source measurement
meteorological factors
energy consumption
control strategy