期刊文献+

Follow-up of endovascular aortic aneurysm repair:Preliminary validation of digital tomosynthesis and contrast enhanced ultrasound in detection of medium- to long-term complications 被引量:1

Follow-up of endovascular aortic aneurysm repair:Preliminary validation of digital tomosynthesis and contrast enhanced ultrasound in detection of medium- to long-term complications
下载PDF
导出
摘要 AIM: To validate the feasibility of digital tomosynthesis of the abdomen(DTA) combined with contrast enhanced ultrasound(CEUS) in assessing complications after endovascular aortic aneurysm repair(EVAR) by using computed tomography angiography(CTA) as the gold standard.METHODS: For this prospective study we enrolled 163 patients(123 men; mean age, 65.7 years) referred for CTA for EVAR follow-up. CTA, DTA and CEUS were performed at 1 and 12 mo in all patients, with a maximum time interval of 2 d.RESULTS: Among 163 patients 33 presented complications at CTA. DTA and CTA correlated for the presence of complications in 32/33(96.96%) patients and for the absence of complications in 127/130(97.69%) patients; the sensitivity, specificity, positive predictive value(PPV), negative predictive value(NPV) and accuracy of DTA were 97%, 98%, 91%, 99%, and 98%, respectively. CEUS and CTA correlated for the presence of complications in 19/33(57.57%) patients and for the absence of complications in 129/130(99.23%) patients; the sensitivity, specificity, PPV, NPV and accuracy of CEUS were 58%, 99%, 95%, 90%, and 91%, respectively. Sensitivity, specificity and accuracy of combining DTA and CEUS together in detecting EVAR complications were 77%, 98% and 95%, respectively.CONCLUSION: Combining DTA and CEUS in EVAR follow-up has the potential to limit the use of CTA only in doubtful cases. AIM: To validate the feasibility of digital tomosynthesis of the abdomen (DTA) combined with contrast enhanced ultrasound (CEUS) in assessing complications after endovascular aortic aneurysm repair (EVAR) by using computed tomography angiography (CTA) as the gold standard.METHODS: For this prospective study we enrolled 163 patients (123 men; mean age, 65.7 years) referred for CTA for EVAR follow-up. CTA, DTA and CEUS were performed at 1 and 12 mo in all patients, with a maximum time interval of 2 d.RESULTS: Among 163 patients 33 presented complications at CTA. DTA and CTA correlated for the presence of complications in 32/33 (96.96%) patients and for the absence of complications in 127/130 (97.69%) patients; the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of DTA were 97%, 98%, 91%, 99%, and 98%, respectively. CEUS and CTA correlated for the presence of complications in 19/33 (57.57%) patients and for the absence of complications in 129/130 (99.23%) patients; the sensitivity, specificity, PPV, NPV and accuracy of CEUS were 58%, 99%, 95%, 90%, and 91%, respectively. Sensitivity, specificity and accuracy of combining DTA and CEUS together in detecting EVAR complications were 77%, 98% and 95%, respectively.CONCLUSION: Combining DTA and CEUS in EVAR follow-up has the potential to limit the use of CTA only in doubtful cases.
出处 《World Journal of Radiology》 CAS 2016年第5期530-536,共7页 世界放射学杂志(英文版)(电子版)
关键词 Digital TOMOSYNTHESIS Contrast enhanced ultrasound ENDOVASCULAR AORTIC ANEURYSM repair FOLLOWUP ENDOVASCULAR AORTIC replacement Digital tomosynthesis Contrast enhanced ultrasound Endovascular aortic aneurysm repair follow-up Endovascular aortic replacement
  • 相关文献

参考文献31

  • 1Brambilla M,Cerini P,Lizio D,Vigna L,Carriero A,Fossaceca R.Cumulative radiation dose and radiation risk from medical imaging in patients subjected to endovascular aortic aneurysm repair. Radiologia Medica . 2015
  • 2Verhoeven E L G,Oikonomou K,Ventin F C,Lerut P,Fernandes E Fernandes R,Mendes Pedro L.Is it time to eliminate CT after EVAR as routine follow-up?. The Journal of cardiovascular surgery . 2011
  • 3Park Jeong Mi,Franken Edmund A,Garg Megha,Fajardo Laurie L,Niklason Loren T.Breast tomosynthesis: present considerations and future applications. Radiographics : a review publication of the Radiological Society of North America, Inc . 2008
  • 4Siegfried Thurnher,Manfred Cejna.??Imaging of aortic stent-grafts and endoleaks(J)Radiologic Clinics of North America . 2002 (4)
  • 5Elliot L. Chaikof,Jan D. Blankensteijn,Peter L. Harris,Geoffrey H. White,Christopher K. Zarins,Victor M. Bernhard,Jon S. Matsumura,James May,Frank J. Veith,Mark F. Fillinger,Robert B. Rutherford,K.Craig Kent.??Reporting standards for endovascular aortic aneurysm repair(J)Journal of Vascular Surgery . 2002 (5)
  • 6HP McAdams,E Samei,Dobbins J 3rd,GD Tourassi,CE Ravin.Recent advances in chest radiography. Radiology . 2006
  • 7de Donato G,Setacci C,Chisci E,Setacci F,Giubbolini M,Sirignano P,Galzerano G,Cappelli A,Pieraccini M,Palasciano G.Abdominal aortic aneurysm repair in octogenarians: myth or reality?. The Journal of cardiovascular surgery . 2007
  • 8Setacci C,De Donato G,Setacci F,Chisci E,Perulli A,Galzerano G,Siringano P.Management of abdominal endograft infection. The Journal of cardiovascular surgery . 2010
  • 9Robert Goetti,Anna Winklehner,Sonja Gordic.Automated Attenuation-Based Kilovoltage Selection: Preliminary Observations in Patients After Endovascular Aneurysm Repair of the Abdominal Aorta. American Journal of Roentgenology . 2012
  • 10White H A,Macdonald S.Estimating risk associated with radiation exposure during follow-up after endovascular aortic repair (EVAR). The Journal of cardiovascular surgery . 2010

共引文献3

同被引文献8

引证文献1

二级引证文献2

相关作者