期刊文献+

Impact of computed tomography image and contact force technology on catheter ablation for atrial fibrillation 被引量:1

Impact of computed tomography image and contact force technology on catheter ablation for atrial fibrillation
下载PDF
导出
摘要 AIM:To investigate the impact of using computed tomography(CT) and contact force(CF) technology on recurrence of atrial tachyarrhythmia after atrial fibrillation(AF) ablation.METHODS: This non-randomized study included 2 groups of patients. All patients had symptomatic recurrent paroxysmal or persistent AF and were treated with at least 1 anti arrhythmic medication or intolerant to medication. The first group included 33 patients who underwent circumferential pulmonary veins isolation(PVI) for AF during 2012 and 2013 guided by CT image integration(Cartomerge, Biosense Webster, Diamond Bar, CA, United States) of left atrium and pulmonary veins into an electroanatomic mapping(EAM) system(CT group) using standard irrigated radiofrequency catheter(Thermo Cool, Carto, Biosense Webster, Diamond Bar, CA, United States) or irrigated catheter with integrated CF sensor(Smart Touch, Carto, Biosense Webster, Diamond Bar, CA, United States). The second group included immediately preceding 32 patients who had circumferential PVI by standard irrigated catheter(Thermo Cool) using only EAM(Carto) system(EAM group). Linear lesions were performed according to the discretion of operator. RESULTS: Sex, age, and persistent AF were not different between groups. PVI was achieved in all patients in both groups. Linear ablations including cavo-tricuspid isthmus and or roof line ablation were not different between groups. Free of atrial tachyarrhythmia during follow-up of 24 mo was significantly higher among CT group compared to EAM group(81% vs 55%; respectively; P = 0.027). When 11 patients from CT group who had ablation using Smart Touch catheter were excluded, the difference between CT group and EAM became non significant(73% vs 55%; respectively; P = 0.16). Sub analysis of CT group showed that patients who had ablation using Smart Touch catheter tend to be more free of atrial tachyarrhythmia compared to patients who had ablation using standard irrigated catheter during follow-up(100% vs 73%; respectively; P = 0.07). Major complications(pericardial effusion, cerebrovascular accident/transient ischemic attack, vascular access injury requiring intervention) did not occurred in both groups.CONCLUSION:These preliminary results suggest that CT image integration and CF technology may reduce the recurrence of atrial tachyarrhythmia after catheter ablation for AF. AIM: To investigate the impact of using computed tomography (CT) and contact force (CF) technology on recurrence of atrial tachyarrhythmia after atrial fibrillation (AF) ablation.METHODS: This non-randomized study included 2 groups of patients. All patients had symptomatic recurrent paroxysmal or persistent AF and were treated with at least 1 anti arrhythmic medication or intolerant to medication. The first group included 33 patients who underwent circumferential pulmonary veins isolation (PVI) for AF during 2012 and 2013 guided by CT image integration (Cartomerge, Biosense Webster, Diamond Bar, CA, United States) of left atrium and pulmonary veins into an electroanatomic mapping (EAM) system (CT group) using standard irrigated radiofrequency catheter (ThermoCool, Carto, Biosense Webster, Diamond Bar, CA, United States) or irrigated catheter with integrated CF sensor (Smart Touch, Carto, Biosense Webster, Diamond Bar, CA, United States). The second group included immediately preceding 32 patients who had circumferential PVI by standard irrigated catheter (ThermoCool) using only EAM (Carto) system (EAM group). Linear lesions were performed according to the discretion of operator.RESULTS: Sex, age, and persistent AF were not different between groups. PVI was achieved in all patients in both groups. Linear ablations including cavo-tricuspid isthmus and or roof line ablation were not different between groups. Free of atrial tachyarrhythmia during follow-up of 24 mo was significantly higher among CT group compared to EAM group (81% vs 55%; respectively; P = 0.027). When 11 patients from CT group who had ablation using Smart Touch catheter were excluded, the difference between CT group and EAM became non significant (73% vs 55%; respectively; P = 0.16). Sub analysis of CT group showed that patients who had ablation using Smart Touch catheter tend to be more free of atrial tachyarrhythmia compared to patients who had ablation using standard irrigated catheter during follow-up (100% vs 73%; respectively; P = 0.07). Major complications (pericardial effusion, cerebrovascular accident/transient ischemic attack, vascular access injury requiring intervention) did not occurred in both groups.CONCLUSION: These preliminary results suggest that CT image integration and CF technology may reduce the recurrence of atrial tachyarrhythmia after catheter ablation for AF.
出处 《World Journal of Cardiology》 CAS 2016年第4期317-322,共6页 世界心脏病学杂志(英文版)(电子版)
关键词 ATRIAL FIBRILLATION CATHETER ablation IMAGE integration Contact force Atrial fibrillation Catheter ablation Image integration Contact force
  • 相关文献

参考文献11

  • 1PETER M.KISTLER,MARK J.EARLEY,STUARTHARRIS,DOMINICABRAMS,STEPHENELLIS,SIMON C.SPORTON,RICHARD J.SCHILLING.??Validation of Three‐Dimensional Cardiac Image Integration: Use of Integrated CT Image into Electroanatomic Mapping System to Perform Catheter Ablation of Atrial Fibrillation(J)Journal of Cardiovascular Electrophysiology . 2006 (4)
  • 2Luigi Sciarra,Paolo Golia,Andrea Natalizia,Ermenegildo Ruvo,Serena Dottori,Antonio Scarà,Alessio Borrelli,Lucia Luca,Marco Rebecchi,Alessandro Fagagnini,Alberto Bandini,Fabrizio Guarracini,Marcello Galvani,Leonardo Calò.??Which is the best catheter to perform atrial fibrillation ablation? A comparison between standard ThermoCool, SmartTouch, and Surround Flow catheters(J)Journal of Interventional Cardiac Electrophysiology . 2014 (3)
  • 3Dong-In Shin,Kiriakos Kirmanoglou,Christian Eickholt,Jan Schmidt,Lukas Clasen,Britta Butzbach,Tienush Rassaf,Marc Merx,Malte Kelm,Christian Meyer.??Initial results of using a novel irrigated multielectrode mapping and ablation catheter for pulmonary vein isolation(J)Heart Rhythm . 2013
  • 4Petr Neuzil,Vivek Y. Reddy,Josef Kautzner,Jan Petru,Dan Wichterle,Dipen Shah,Hendrik Lambert,Aude Yulzari,Erik Wissner,Karl-Heinz Kuck.??Electrical Reconnection After Pulmonary Vein Isolation Is Contingent on Contact Force During Initial Treatment: Results From the EFFICAS I Study(J)Circulation: Arrhythmia and Electrophysiology . 2013 (2)
  • 5The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study(J)Heart Rhythm . 2012 (11)
  • 6Hugh Calkins,Karl Heinz Kuck,Riccardo Cappato,Josep Brugada,A. John Camm,Shih-Ann Chen,Harry J.G. Crijns,Ralph J. Damiano,D. Wyn Davies,John DiMarco,James Edgerton,Kenneth Ellenbogen,Michael D. Ezekowitz,David E. Haines,Michel Haissaguerre,Gerhard Hindricks,Yoshito Iesaka,Warren Jackman,José Jalife,Pierre Jais,Jonathan Kalman,David Keane,Young-Hoon Kim,Paulus Kirchhof,George Klein,Hans Kottkamp,Koichiro Kumagai,Bruce D. Lindsay,Moussa Mansour,Francis E. Marchlinski,Patrick M. McCarthy,J. Lluis Mont,Fred Morady,Koonlawee Nademanee,Hiroshi Nakagawa,Andrea Natale,Stanley Nattel,Douglas L. Packer,Carlo Pappone,Eric Prystowsky,Antonio Raviele,Vivek Reddy,Jeremy N. Ruskin,Richard J. Shemin,Hsuan-Ming Tsao,David Wilber.??2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Patient Selection, Procedural Techniques, Patient Management and Follow-up, Definitions, Endpoints, and Research Trial Design(J)Heart Rhythm . 2012 (4)
  • 7Christopher Piorkowski,Charlotte Eitel,Sascha Rolf,Kerstin Bode,Philipp Sommer,Thomas Gaspar,Simon Kircher,Ulrike Wetzel,Abdul Shokor Parwani,Leif-Hendrik Boldt,Meinhard Mende,Andreas Bollmann,Daniela Husser,Nikolaos Dagres,Masahiro Esato,Arash Arya,Wilhelm Haverkamp,Gerhard Hindricks.??Steerable Versus Nonsteerable Sheath Technology in Atrial Fibrillation Ablation: A Prospective, Randomized Study(J)Circulation: Arrhythmia and Electrophysiology . 2011 (2)
  • 8Peter M. Kistler,Kim Rajappan,Stuart Harris,Mark J. Earley,Laura Richmond,Simon C. Sporton,Richard J. Schilli.The impact of image integration on catheter ablation of atrial fibrillation using electroanatomic mapping: a prospective randomized study. European Heart Journal . 2008
  • 9Piorkowski Christopher,Kircher Simon,Arya Arash,Gaspar Thomas,Esato Masahiro,Riahi Sam,Bollmann Andreas,Husser Daniela,Staab Charlotte,Sommer Philipp,Hindricks Gerhard.Computed tomography model-based treatment of atrial fibrillation and atrial macro-re-entrant tachycardia. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology . 2008
  • 10Roten Laurent,Derval Nicolas,Pascale Patrizio,Scherr Daniel,Komatsu Yuki,Shah Ashok,Ramoul Khaled,Denis Arnaud,Sacher Frederic,Hocini Meleze,Haissaguerre Michel,Jais Pierre.Current Hot Potatoes in Atrial Fibrillation Ablation. Current Cardiology Reviews . 2012

同被引文献7

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部