碳纤维膜负载组合光敏剂去除重革废水中S^(2-)、有机物的研究 被引量:1

Study on treatment of vegetable tanning waste water with photosensitive oxidation of complex photosensitiser loaded in carbon fibre membrane
下载PDF
导出
摘要 提出了一种利用碳纤维膜负载组合光敏剂、光敏氧化处理重革废水的新技术。结果显示 :光敏剂的不同组合及碳纤维膜负载不同量的光敏剂 ,对制革废水中S2 -、COD的去除率是不同的 ,其中以负载复合型光敏剂 ,即当吖靛橙 (RO)∶亚甲基蓝 (MB) =3∶2 ,总负载量为 1 80mg/m2 为最佳。在光照强度为 3 0 0 0lx ,面积负荷为94L/m2 ·HRT ,S2 -的去除率在 90 .0 %以上、COD去除率也可达 5 9.7% :对有机物的最大去除能力为 1 65 g(COD) /m2 ·HRT ,并且这种负载型光敏剂可重复使用。 This new method of treating vegetable tanning waste water by photosensitive oxidation of complex photosensitiser (acridine orange and methylene blue) loaded in carbon fibre membrane is presented.The test results show the different ratios of removing S 2- ,COD contrast with the different quality of complex photosensitisers and their loaded quality. The best efficiency of removing S 2- is more than 90.0%and COD is about 59.7%,the max oxidation ability is 165g(COD)/m 2·HRT,under the conditions as follows:RO∶MB=3∶2,the quality of total loaded amount 180mg/m 2,lighting intension 3 000lx,HRT=2h,and area burdening amount 94L/m 2·HRT.In the same time the complex photosensitisers loaded can be reused,the mechanisms are also discussed.
作者 刘德启
出处 《中国皮革》 CAS 北大核心 2003年第21期9-11,共3页 China Leather
关键词 碳纤维膜负载组合光敏剂 光敏氧化处理 重革废水 制革废水 废水处理 carbon fibre membrane loaded complex photosensitisers photosensitive oxidation vegetable tanning waste water