期刊文献+

锶原子光晶格钟黑体辐射频移评估 被引量:2

Evaluation of blackbody-radiation frequency shift in strontium optical lattice clock
下载PDF
导出
摘要 在中性原子光晶格钟的系统不确定度评估中,通常黑体辐射引起的频移是最大的一项.黑体辐射频移主要受周围环境温度的影响.针对国家授时中心的锶原子光晶格钟实验系统,通过理论分析、腔体表面温度的测量和软件模拟相结合的方法,评估了锶原子光晶格钟黑体辐射频移的修正量和不确定度.其中主要分析了锶原子炉、蓝宝石加热窗口、透过窗口片进入到真空腔体内的室温以及Zeeman减速装置对原子团处的热辐射引起的黑体辐射频移.在真空腔体外表面设置了5个测温点,利用校准过的铂电阻温度传感器监测真空腔体外表面的温度变化,用SolidWorks绘图软件建立腔体模型,通过有限元分析软件模拟出在真空腔体温度变化0.72 K时,原子团所处位置温度的波动为0.34 K.最终得到黑体辐射频移总的修正量为-2.13(1) Hz,不确定度为2.4×10^(-17). The frequency shift caused by blackbody radiation is one of the dominant corrections to the evaluation of the optical lattice clock.The frequency shift of blackbody radiation is closely related to the dynamic and static correction factor,ambient temperature and atomic polarizability.The blackbody radiation shift is mainly affected by ambient temperature.During the normal operation of the strontium atom optical lattice clock,the experimental environment and other heat sources around the vacuum cavity have complicated the environment around the vacuum cavity,resulting in the fact that the external surface temperature of the vacuum cavity does not truly reflect the temperature change of the vacuum cavity.For the strontium atomic optical clock experimental apparatus of the National Time Service Center,the uncertainty and correctionof the blackbody radiation frequency shift are evaluated by the theoretical analysis,measurement of the temperature of the vacuum cavity outer surface,and software simulation.Among them,the frequency shift of black body radiation caused by strontium atom furnace,sapphire heating window,room temperature radiation entering into the vacuum cavity through the window plate,and the thermal radiation at the atomic group caused by Zeeman reducer are analyzed.Five temperature measuring points are set on the external surface of the vacuum chamber,and the temperature changes on the external surface of the vacuum chamber are monitored in real time by using the calibrated platinum resistance temperature sensor while the system is running normally.We obtain the average temperature of the five temperature measuring points.The model of vacuum cavity is established by using the SolidWorks.The method of finite element analysis is used to simulate the variation of the temperature around atom samples.We also obtain the temperature distribution around the atomic groups in the vacuum cavity.The result shows that the temperature around atoms varies with the temperature of the vacuum cavity.When the temperature of the ambient temperature changes 0.72 K,the fluctuation of the temperature around the atoms is 0.34 K.Finally,the total correction of blackbody radiation of the system is evaluated to be-2.13(1)Hz,and the correction uncertainty is about 2.4×10-17.
作者 李婷 卢晓同 张强 孔德欢 王叶兵 常宏 Li Ting;Lu Xiao-Tong;Zhang Qiang;Kong De-Huan;Wang Ye-Bing;Chang Hong(Key Laboratory of Time and Frequency Primary Standards of Chinese Academy of Sciences,National Time Service Center,Xi’an 710600,China;School of Astronomy and Space Science,University of Chinese Academy of Sciences,Beijing 100049,China;College of Physics and Materials Science,Henan Normal University,Xinxiang 453007,China)
出处 《物理学报》 SCIE EI CAS CSCD 北大核心 2019年第9期110-117,共8页 Acta Physica Sinica
基金 国家自然科学基金(批准号:11803042 11474282 61775220) 中国科学院前沿科学重点研究项目(批准号:QYZDB-SSWJSC004) 中国科学院国家授时中心青年创新人才项目资助的课题~~
关键词 锶原子光晶格钟 热辐射 黑体辐射频移 有限元分析 strontium optical lattice clock thermal radiation blackbody radiation shift finite element analysis
  • 相关文献

同被引文献4

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部