期刊文献+

基于GEANT4的工业CT微通道板探测器特性模拟

The Characteristics Simulation of Industrial CT Micro-channel Plate Detector Based on GEANT4 Toolkits
下载PDF
导出
摘要 基于GEANT4工具包及使用225kV最高管电压X射线机,探讨了在不同的X射线入射能量下,改变微通道板工作电压及几何参数时,增益、探测效率及空间分辨率的特性变化情况,为实际应用提供了参考。结果表明:微孔直径20μm、长径比40、开口面积60%、偏角8°;工作电压970V,工作环境真空度10-3Pa时,微通道板探测器能满足工业CT系统的要求。 Based on the GEANT4 toolkit and an X ray machine whose maximum tube voltage was 225 kV,the characteristic changes of the gain,the detection efficiency and also the spatial resolution of the X-ray detector were studied through the working voltage and geometric parameters of the micro-channel plate under different incident energies.It can provide a reference for practical application.Study confirms that the micro-channel plate detector can meet the requirement of industrial CT system proving the following settings are met:the micro pore diameter of20μm,length to diameter ratio of 40,the opening area of 60%,angle of 8°,working voltage of 970 Vand the working environment of vacuum degree 10-3 Pa.
出处 《无损检测》 2014年第8期1-6,共6页 Nondestructive Testing
基金 兰州大学自然科学类中央高校基本科研专项资助项目(860452)
关键词 微通道板 工业CT GEANT4 探测器 Micro-channel plate Industrail CT GEANT4 Detector
  • 相关文献

参考文献16

  • 1苏吉,王化祥,薛倩,郝魁红.基于Geant4的γ-CT系统优化设计[J].核技术,2011,34(8):575-580. 被引量:2
  • 2周日峰,陈伟民,段晓礁.基于气体电子倍增器原理的高能X射线工业CT气体探测器[J].原子能科学技术,2011,45(6):741-745. 被引量:4
  • 3潘京生.微通道板及其主要特征性能[J].应用光学,2004,25(5):25-29. 被引量:52
  • 4张多明.&nbsp&nbsp微通道板[J].物理.1986(09)
  • 5赵世诚,于长海,王黎君.微通道板X射线探测器[J]核聚变与等离子体物理,1985(03).
  • 6计算机层析成像检测[M]. 机械工业出版社, 2006.计算机层析成像检测[M]机械工业出版社,2006.
  • 7原子物理学[M]. 高等教育出版社, 2000.原子物理学[M]高等教育出版社,2000.
  • 8Umesh Kumar,G.S. Ramakrishna,A.S. Pendharkar,Gursharan Singh.Behaviour of reconstructed attenuation values with X-ray tube voltage in an experimental third-generation industrial CT system using Xscan linear detector array[J]. Nuclear Inst. and Methods in Physics Research, A . 2002 (1)
  • 9Allison, J.,Amako, K.,Apostolakis, J.,Araujo, H.,Dubois, P. Arce,Asai, M.,Barrand, G.,Capra, R.,Chauvie, S.,Chytracek, R.,Cirrone, G.A.P.,Cooperman, G.,Cosmo, G.,Cuttone, G.,Daquino, G.G.,Donszelmann, M.,Dressel, M.,Folger, G.,Foppiano.Geant4 developments and applications. IEEE Transactions on Nuclear Science . 2006