阐述了商场空调设计中新风量取值与人流密度的关系 ,就空调系统形式对能耗的影响进行了分析 ,提出了以集中送风系统为主 。
Combined with practical national conditions the relationship between fresh air volume determination in air conditioning system design and population density is elaborated. And based upon analysis of the influences of modes of air conditioning system the idea that based upon central air supply system and combined with distributed system is proposed.