期刊文献+

P_(ET)CO_2监测在胸段硬膜外麻醉病人中的应用 被引量:1

The application of monitoring P_(ET) CO_2 to the patients during thoracic epidural anesthesia
下载PDF
导出
摘要 目的 为了评价胸段硬膜外阻滞中经鼻导管至咽后壁监测PETCO2 的必要性和准确性。方法 对 2 8例上腹部手术病人胸段硬膜外阻滞过程中各时相点PETCO2 和PaCO2 的变化 ,以及两者之间的相关性进行观察。结果 麻醉中PaCO2 和PETCO2 增高有显著性意义 (P <0 .0 1) ;PETCO2 和PaCO2 两者之间呈正相关 (r =0 .814 ,P <0 .0 0 1) ,PETCO2 能真实反映PaCO2 值。结论 鼻插管至咽后壁监测PETCO2 方法简单、易行、无创 ,建议将PETCO2 Objective To evaluate the necessity and accuracy of monitoring P ET CO 2 during the thoracic epidural anesthesia.Methods The variety and relativity of P ET CO 2 and PaCO 2 in every time for 28 cases,which were operated in thoracic epidural anesthesia of midsection,were observed.Results With hightened P ET CO 2 and PaCO 2,there was significant difference in anesthesia.And there was positive correlation between two values.The value of PaCO 2 could be expressed P ET CO 2 truly.Conclusion The monitoring P ET CO 2 can be a routine of thoracic epidural anesthesia.
作者 江敏林
出处 《宁夏医学杂志》 CAS 2003年第12期727-728,共2页 Ningxia Medical Journal
关键词 硬膜外麻醉 二氧化碳分压测定 Thorax Epidural anesthesia Carbon dioxide partial pressure dctermination
  • 相关文献

参考文献2

二级参考文献4

  • 1袁玉如,实用危重病监测治疗学,1998年,72页
  • 2赵俊,重症监测治疗与复苏,1991年,106页
  • 3张国楼,中华麻醉学杂志,1988年,8卷,286页
  • 4张国楼,临床麻醉学杂志,1986年,2卷,68页

共引文献9

同被引文献11

  • 1陈卉.Bland-Altman分析在临床测量方法一致性评价中的应用[J].中国卫生统计,2007,24(3):308-309. 被引量:217
  • 2Eskaros SM,Papadakos P,Lachmann B.Chapter 44,Respiratory monitoring[M] //Miller RD,Eriksson LI,Fleisher LA,et al.Miller's Anesthesia.7th Edition.Elsevier,2009.
  • 3Raheem MSA,Wahba OM.A nasal catheter for the measurement of end-tidal carbon dioxide in spontaneously breathing patients:a preliminary evaluation[J].Anesth Analg,2010,110(4):1039-1042.
  • 4Soto RG,Fu ES,Vila H Jr,et al.Capnography accurately detects apnea during monitored anesthesia care[J].Anesth Analg,2004,99(2):379-382.
  • 5Deitch K,Miner J,Chudnofsky CR,et al.Does end tidal CO《,2》 monitoring during emergency department procedural sedation and analgesia with propofol decrease the incidence of hypoxic events? A randomized,controlled trial[J].Ann Emerg Med,2010,550):258-264.
  • 6Sandlin D.Capnography for nonintubated patients:the wave of the future for routine monitoring of procedural sedation patients[J].J Perianesth Nuts,2002,17(4):277-281.
  • 7Nishiyama T,Hanaoka K.Usefulness of a new nasal cannula with an end-tidal carbon dioxide measuring port[J].Masui,2003,2(4):424-426.
  • 8李镒冲,李晓松.两种测量方法定量测量结果的一致性评价[J].现代预防医学,2007,34(17):3263-3266. 被引量:154
  • 9莫家全,黄坚,陈剑波,顾彩洁,唐波.呼气末二氧化碳分压监测用于非全麻甲状腺手术的体会[J].国际医药卫生导报,2008,14(5):22-23. 被引量:2
  • 10瞿艳新,江敏林.PETCO_2监测在老年人胸段硬膜外麻醉中的应用[J].中国医学创新,2010,7(1):9-10. 被引量:3