摘要  利用放电等离子烧结(SPS)制备了Ti/HA复合材料,研究了不同配比的Ti/HA复合材料的显微组织、致密度及pH值,并进行了生物溶血试验。结果表明:经颗粒表面钝化处理后,50%Ti-50%HA复合材料的相对密度由73%提高到94.4%,pH值保持中性,溶血试验指标为4%,符合生物材料的应用要求。 Ti/HA composites were manufactured by spark plasma sintering (SPS). The microstructure, density and the pH value for Ti/HA samples with different proportions were studied. The biological hemolytic experiment was done. The result indicates that when the particles are passivated before sintering the relative density of the 50%Ti-50%HA composite increases from 73% to 94.4%, the pH value remains neutral and the biological hemolytic experiment index is 4%, which meets the application demand of bioactivity materials.
出处 《复合材料学报》 EI CAS CSCD 北大核心 2003年第6期57-60,共4页 Acta Materiae Compositae Sinica
基金 教育部跨世纪优秀人才计划基金
关键词 生物活性材料 放电等离子烧结 钝化 Hydroxyapatite Microstructure Passivation pH Sintering Titanium
  • 相关文献

参考文献4

二级参考文献28

  • 1王迎军,宁成云,刘正义,陈楷,陈汉存.金属基等离子喷涂HA涂层人工骨的研究[J].中国陶瓷,1996,32(4):37-40. 被引量:6
  • 2山口乔.生物陶瓷[M].化学工业出版社,1992..
  • 3陈佳洱.等离子体物理学[M].北京:科学出版社,1994.14.
  • 4田增英.来自西方的知识--精密陶瓷的应用[M].北京:科学出版社,1993..
  • 5南策文 陈政新.Ti-Al2O3金属陶瓷的渗流模型.物理学报,1987,36.
  • 6高濂,宫本大树.放电等离子烧结技术[J].无机材料学报,1997,12(2):129-133. 被引量:117
  • 7汪得灌.计算水力学理论与应用[M].南京:河海大学出版社,1989..
  • 8金忠清.N-S方程的数值解和紊流模型[M].南京:河海大学出版社,1989..
  • 9傅德薰.流体数值模拟[M].北京:国防工业出版社,1993..
  • 10中国水利水电科学研究院.西龙池抽水蓄能电站(分岔管)模型试验报告[R].,2002..

共引文献174

同被引文献13

  • 1邹俭鹏,阮建明,黄伯云,刘建本,周小霞.Physico-chemical properties and microstructure of hydroxyapatite-316L stainless steel biomaterials[J].Journal of Central South University of Technology,2004,11(2):113-118. 被引量:5
  • 2Okada S, Kashino T, Kin Y, et al. Morphological changes and bone formation in cortical bone around hydroxyapatite cement in experimental osteoporotic rats [J]. Journal of Materials Science Letters, 2002, 21(12): 971-973.
  • 3Reclaru L, Lerf R, Eschler P Y, et al. Corrosion behavior of a welded stainless-steel orthopedic implant [J]. Biomaterials, 2001, 22(3): 269-279.
  • 4Dunn D S, Raghavan S, Volz R G. Anodized layers on titanium and titanium alloy orthopedic materials for antimicrobial activity applications [J]. Materials and Manufacturing Processes, 1992, 7(1): 123-137.
  • 5Prabhu A, Shelburne C E, Gibbons D F. Cellular proliferation and cytokine responses of murine macrophage cell line J774A. 1 to polymethylmethacrylate and cobalt-chrome alloy particles [J]. Journal of Biomedical Materials Research,1998, 42(4): 655-663.
  • 6Hellier W G, Hedman T P. Wear volume rates of forged and hot isostatically pressed powder cobalt-chromium-molybdenum alloy for an intervertebral disc prosthesis [A]. Transac tions of the Annual Meeting of the Society for Biomaterials in Conjunction with the International Biomaterials Symposium[C]. 1991, 14: 224-229.
  • 7Cottrell A H. Strong solids [J]. Proc Roy Soc, 1964, A282(1): 2-9.
  • 8Knepper M, Milthorpe B K. Interdiffusion in short-fibre reinforced hydroxyapatite ceramics [J]. Journal of Materials Science: Materials in Medicine, 1998, 9(10): 589-596.
  • 9白晓军,金展鹏,曾强,黎樵燊.不锈钢基体上Ni-HAP复合镀层结合强度的研究[J].电镀与环保,2000,20(1):6-8. 被引量:3
  • 10齐宝芬.外科植入不锈钢产品钝化工艺[J].材料保护,2000,33(5):37-38. 被引量:1

引证文献1

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部