期刊文献+

非共沸混合工质热泵系统节能机理研究(英文)

Research on the Heat Pump Systems in Saving Energy Using Nonazeotropic Refrigerant Mixtures
下载PDF
导出
摘要 从经典热力学的基本理论出发 ,结合热源的特点 ,深入研究了制冷工质和热源间的温度匹配性能MPC与传热不可递损失之间的关系 。 Based on the fundamental theory of classical thermodynamics and the nature of heat sources,the matching performance criterion between mixtures and heat sources in a cycle,which was named as C ,has been obtained.The characteristic of saving energy of refrigerant mixtures was revealed and discussed theoretically.
出处 《湖南文理学院学报(自然科学版)》 CAS 2003年第4期12-14,共3页 Journal of Hunan University of Arts and Science(Science and Technology)
关键词 非共沸混合工质热泵系统 节能机理 热力学分析 温度匹配 制冷工质 热源 Heat Pump Refrigerant Mixture Saving Energy Thermodynamic Analyzing
  • 相关文献

参考文献2

  • 1[1]Vineyard, E. A. Selection of Ozone-Safe, Non-azeotropic Refrigerant Mixtures for Capacity Modulation in Residential Heat Pumps[J].ASHRAE Trans. 1989,95:34-45.
  • 2[2]McLinden, M. O. Methods for comparing the performance of pure and mixed refrigerants in the vapour compression cycle [J]. International Joural of Refrigeration, 1987.10:318-325.