摘要
在原控制方法难以使燃烧器达到燃烧要求的情况下,在现场通过改变电气控制原理使燃烧器顺利点火,并且各种负荷下燃烧稳定,介绍了改进的实例。
The originally existing way of control of a certain oil fired boiler couldn't make the combustor meet combustion requirements. After on site application of an alternative principle, the combustor effectuated smooth ignition and moreover, stable combustion at various loads. The paper presents an introduction to this practical example.