期刊文献+

插入式耳机在纯音听阈测试中的应用 被引量:5

Use of Insert Earphone in Pure Tone Audiometry
下载PDF
导出
摘要 目的 探讨标准插入式耳机的耳间衰减值。方法 将 75名年龄 12~ 6 8岁的一耳听力正常 ,另一耳重度到极重度感音神经性聋的受试者 (男 4 7名 ,女 2 8名 ) ,随机分为两组 ,分别以TDH - 39压耳式耳机 (n =4 6 )和ER - 3A标准插入式耳机 (n =2 9)进行耳间衰减值的测量及比较。结果 ①ER - 3A插入式耳机的耳间衰减最大值为 10 5dB ,最小值为 5 5dB ,TDH - 39压耳式耳机的耳间衰减最大值为 90dB ,最小值为 4 5dB ;②对不同耳机组 ,不同频率的耳间衰减值进行双因素方差分析 (耳机×频率 ) ,两种耳机的耳间衰减的差异具有显著性 (F =6 8.5 2 6 ,P =0 .0 0 0 ) ,各个频率耳间衰减的差异也具有显著性 (F =10 .4 16 ,P =0 .0 0 0 ) ;③在插入式耳机组中 ,不同频率的耳间衰减值经单因素方差分析 ,其差异有显著性意义 (F =11.6 30 ,P =0 .0 0 )。结论 插入式耳机因为增大了耳间衰减 ,从而减少了交叉听力及超掩蔽的可能 。 Objective To investigate the inter-aural attenuation of the standard insert phone.Methods 75 severe to profound sensori-neural hearing impaired people aged from 12 to 68 were randomly divided into two groups. Inter-aural attenuation was tested either by TDH-39 ( n =46) or by ER-3A insert phone ( n =29). The data was processed by SPSS software.Results The maximum and minimum inter-aural attenuations of ER-3A were 105 and 55 dB, and 90 and 45 dB of TDH-39.2-way repeated measure ANOV (phone×frequency)showed there existed significant difference both between the two earphones ( F =68.526, P =0.000) and among the frequencies ( F =10.416, P =0.000). ANOV indicated statistical significance between frequencies in insert phone ( F =11.630, P =0.00). Conclusion By increasing the inter-aural attenuation, insert phone could in some degree solve the masking dilemma encountered by TDH-39.
出处 《听力学及言语疾病杂志》 CAS CSCD 2004年第1期23-24,共2页 Journal of Audiology and Speech Pathology
关键词 插入式耳机 耳间衰减 耳聋 诊断 纯音听阈测试 Insert phone Inter-aural attenuation
  • 相关文献

参考文献9

  • 1[1]Beverly A,Goldstein and Craig W,Newman. Clinical masking: A decision masking process. Jack Katz. Handbook of clinical audiology[M]. Baltimore: Williams & Wilkins, 1994.109~131.
  • 2[2]Frank T,Vavrek MJ.Reference threshold levels for an ER-3A insert earphone[J]. J Am Acad Audiol,1992,3:51.
  • 3[3]Daniel A,Sklare & Larry J,Denenberg. Interaural attenuation for tubephone insert earphones[J]. Ear and Hearing, 1987,7:298.
  • 4[4]Clemis JD, Ballad WJ, Killion MC. Clinical use of an insert earphone[J].Ann Otol Rhinol Larngol,1986,95:520.
  • 5[5]Frank T, Wright DC. Attenuation provided by four different audiometric earphone systems[J].Ear Hear,1990,11:70.
  • 6[6]Blackwell KL,Oyler RF,Seyfried DN, A clinical comparison of Grason Stadler insert earphones and TDH-50P standard earphones[J]. Ear Hear, 1991,12:361.
  • 7[7]Luks SB, Borton TE, Nolen BL. Insert earphones for audiometry: application, advantages and limitations[J].Entechnology,1989,28:61.
  • 8[8]Hosford-Dunn H.Solving audiometric masking dilemmas with an insert masker[J].Arch Otolaryngol Head Neck Surg, 1986,112:92.
  • 9[9]Hall, JW, 3rd and JH Grose.The effect of conductive hearing loss on the masking-level difference: insert versus standard earphones[J].J Acoust Soc Am,1994,95:2 652.

同被引文献33

  • 1杨长亮,黄治物,高胜利,常伟.压耳式及插入式耳机给声诱发听性脑干反应[J].听力学及言语疾病杂志,2005,13(4):248-250. 被引量:1
  • 2陈洪文,顾瑞,仇春燕.ER-3A插入式耳机的基准等效阈声压级测试[J].听力学及言语疾病杂志,1996,4(3):125-127. 被引量:1
  • 3Intelligent Hearing Systems Pty Ltd. Smart Ep-ASSR auditory steady state responses evoked potential system manual[M].Version 2.05 .Miami,Florida,USA,2003,28~29.
  • 4Dimitrijevic A,John MS,Van Roon P, et al. Estimating the audiogram using multiple auditory steady-state response[J]. J Am Acad Auditol,2002,13:205.
  • 5Rance G,Rickards F.Predition of hearing threshold in infants using auditory steady-state evoked potentials[J]. J Am Acad Auditol,2002,13:236.
  • 6Vander KR,Brown CJ,Gienapp BA,et al.Comparison of auditory steady-state response thresholds in children[J]. J Am Acad Auditol,2002,13:227.
  • 7Perez-Abalo MC,Savio G,Torres A,et al.Staedy state reponses to multiple amplitude-modulated tones:an optimized method to test frequency-specific thresholds in hearing-impaired children and normal-hearing subjects[J].Ear Hear,2001,22:200.
  • 8Lins OG,Picton TW,Boucher BL,et al.Frequency-specific audiometry using steady-state responses[J].Ear Hear,1996,17:81.
  • 9Cone-Wesson B,Dowell RC,Tomlin D,et al.The auditory steady-state response:comparisons with the auditory brainstem response[J].J Am Acad Auditol,2002,13:173.
  • 10Herdman AT,Stapells DR.Auditory steady state response thresholds of adults with sensorineural hearing impairment[J].Int J Audiol,2003,42:237.

引证文献5

二级引证文献37

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部