通过对小型水溶性液体灭火试验数据的分析 ,试图找出水溶性液体在水中的溶解度、闪点、燃烧热等理化性能指标对泡沫混合液供给强度与供给时间的影响 ,探讨现行《低倍数泡沫灭火系统设计规范》
Based on the analysis and study the data in small F oam Extinguishing test for Water-soluble flammable and combustible liquids,tri ed to find the influence of solubility in water and flash point of water-solubl e flammable and combustible liquids on foam solution application rate and discha rge times. Discussed to minimum alcohol-resistant foamsapplication rate and d ischarge times for fixed-roof tanks containing water-soluble flammable and com bustible liquids without implementing. Code for Design of Low Exqansion Foam Ex tinguishing Systems.
出处
《消防科学与技术》
CAS
2003年第6期494-496,共3页
Fire Science and Technology
关键词
水溶性液体
固定顶储罐
泡沫混合液
供给强度
灭火
water-soluble flammable and combustible liquids
F ixed-roof storage tanks
foam solution application rate