600MW机组锅炉蒸汽温度和烟气温度偏低的原因分析及解决措施

Cause and action taken for lower boiler vapour temperature and fume temperature of 600 MW power generators
下载PDF
导出
摘要 针对某电厂3号炉运行煤种偏离设计煤质、设计炉膛沾污系数相对偏大造成空气预热器入口烟温、主汽温、再热汽温不能达到设计值等问题,进行了锅炉试验测定和问题原因分析,制定了最终的改造方案。实践证明,通过调整对流受热面面积,将过热器末段间连接交叉布置改为平行布置,能够提高空气预热器入口烟温、主汽温和再热汽温,降低过热器热偏差,提高锅炉效率。 The quality of coal used in No.3 Boiler of a power plant under the designed coal quality and the relatively higher store chamber contamination coefficient caused the failure of the fume temperature at the inlet of air preheater, principal steam temperature and temperature of reheated steam to reach the designed values. An updating scheme was worked out through boiler test and trouble shooting. Practice proved that the change in the overheater end connection from cross arrangement to parallel arrangement can increase the air preheater inlet fume temperature, principal steam temperature and reheated steam temperature, and reduce the thermal deviation of overheater, and improve the efficiency of boiler.
出处 《黑龙江电力》 CAS 2003年第6期451-454,共4页 Heilongjiang Electric Power
关键词 锅炉 热偏差 炉膛沾污系数 温度 受热面 boiler thermal different store chamber contamination coefficient temperture heat-exchange surface
  • 相关文献

参考文献3

二级参考文献14

  • 1杨君义.四角切圆燃烧方式锅炉水平烟道中的烟气偏差.锅炉燃烧技术学术会议论文集[M].哈尔滨:中国动力工程学会锅炉专业委员会,1996.65-68.
  • 2徐通模 惠世恩 等.300MW、600MW引进型切向燃烧锅炉烟气偏差的实验研究与数值模拟[M].西安:西安交通大学,1998..
  • 3贾鸿祥 许晋源.切圆燃烧煤粉炉燃尽区速度场的研究[J].动力工程,1985,(2):21-27.
  • 4阎维平,锅炉技术,1999年,5期,1页
  • 5徐通模,300MW、600MW引进型切向燃烧锅炉烟气偏差的实验研究与数值模拟,1998年
  • 6杨君义,锅炉燃烧技术学术会议论文集,1996年,65页
  • 7Mo Xutong,The Proceeding of ICOPE,1995年,305页
  • 8贾鸿祥,动力工程,1985年,2期,21页
  • 9刘庆红,600MW级机组锅炉学术讨论会论文集,1998年,9页
  • 10相大光,600MW级机组锅炉学术讨论会论文集,1998年,9页

共引文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部