水箱中辅助电加热器的位置对自然循环太阳能热水系统运行特性的影响

EFFECTS ON PERFORMANCE OF A THERMOSYPHON SOLAR WATER HEATER WITH AN AUXILIARY ELECTRIC HEATER EXERTED BY LOCATIONS OF THE ELECTRIC HEATER IN THE STORAGE TANK
下载PDF
导出
摘要 利用“固定节点等量对流混合模型”,探讨了水箱中辅助电加热器的位置对自然循环太阳能热水系统运行特性的影响,揭示出一些未知的规律,为该系统优化设计和实际应用奠定了基础。 Based on the 'fixed-node, equally-convected mixing model' developed by the authors, a detailed theoretical simulations on the system performance exerted by locations of the electric heater in the tank was worked out. The simulation results showed some new characteristics of the system with the electric heater exerted in the storage tanke. It would be useful to the design and operation of such system.
出处 《太阳能学报》 EI CAS CSCD 北大核心 1992年第4期327-333,共7页 Acta Energiae Solaris Sinica
关键词 太阳能 热水系统 水箱 电加热器 auxiliary electric heater, thermosyphon solar water heater, performance simulation, optimazation
  • 相关文献

参考文献2

  • 1林文贤,Energy Convers Mgmt,1991年,31卷,409页
  • 2林文贤,云南师范大学学报,1991年,11卷,2期,28页

相关作者