期刊文献+

不同电参数对CFRC应变敏感性的响应 被引量:2

Response of Different Electric Parameter to Strain-sensing Ability of CFRC
下载PDF
导出
摘要 CFRC具有压敏性 ,测试方法和测试参数的选择对 CFRC的压敏性有一定的影响。采用直流电阻测试法、交流阻抗测试法和电容测试法研究了不同电参数 (直流电阻、交流阻抗、电容 )对 CFRC应变敏感性的响应。实验结果表明 :直流电阻和交流阻抗随压力的变化都能反映试样受载变形的全过程 :弹性阶段、损伤阶段、破坏阶段 ;电容随压力的增大而增大 ;交流阻抗和电容随应变的变化比直流电阻随应变的变化灵敏且稳定。最后对这 3种测试方法作了综合评价。 The carbon fiber reinforced cement(CFRC) has pressure sensibility. The selection of measuring technique and parameter has an effect on the pressure sensibility of CFRC. In this paper, the response of different electric parameter (dc resistance and ac impedance and capacity )to strain-sensing ability of CFRC has been studied by dc resistance and ac impedance and capacity measuring techniques. The results showed that the change of ac impedance and capacity with stress-strain is more sensitive and stabler than that of dc resistance. Finally, the three measuring technique were reviewed and compared.
出处 《武汉理工大学学报》 CAS CSCD 2004年第1期35-37,75,共4页 Journal of Wuhan University of Technology
基金 国家自然科学基金 (5 0 2 380 4 0 )
关键词 CFRC 直流电阻 交流阻抗 电容 应变敏感性 CFRC dc resistance ac impedance capacity strain-sensing ability
  • 相关文献

参考文献10

  • 1Chen Puwei,Chung D D L.Carbon Fiber Reinforced Concrete for Smart Structures Capable of Non-destructive Flow Detection[J].Smart Mater Structure,1993,(2):22~30.
  • 2毛起,赵斌元,沈大荣,李卓球.水泥基碳纤维复合材料压敏性的研究[J].复合材料学报,1996,13(4):8-11. 被引量:74
  • 3毛起,杨元霞,李卓球,沈大荣.碳纤维增强水泥压敏性影响因素的研究[J].硅酸盐学报,1997,25(6):734-737. 被引量:27
  • 4Fu X, Chung D D L.Self-monitoring of Fatigue Damage in Carbon Fiber Reinforced Cement[J].Cement and Concrete Research,1996,26(1):15~20.
  • 5Fu X, Lu W, Chung D D L.Effect of Curing Age on the Self-monitoring Behavior of Carbon Fiber Reinforced Mortar[J].Cement and Concrete Research,1997,27(9):1313~1318.
  • 6Dragos Marian, Chung D D L.Damage in Carbon Fiber-reinforced Concrete Monitored by Electrical Resistance Measurement[J]. Cement and Concrete Research, 2000,30(4):651~659.
  • 7Xu Yunsheng,Chung D D L.Cement-based Materials Improved by Surface Treated Admixtures[J].ACI Mater J,2000,97(3):333~342.
  • 8张楚风 孙根华 温文声.实用电工学[M].北京:人民邮电出版社,1986..
  • 9郑立霞,宋显辉,李卓球,王建军.碳纤维增强水泥在受压时的电容测量[J].混凝土,2003(3):25-26. 被引量:9
  • 10Wen Sihai, Chung D D L.Cement-based Materials for Stress Sensing by Dielectric Measurement[J]. Cement and Concrete Research,2002,2063:1~5.

二级参考文献16

  • 1毛起,赵斌元,沈大荣,李卓球.水泥基碳纤维复合材料压敏性的研究[J].复合材料学报,1996,13(4):8-11. 被引量:74
  • 2郭全贵,新型碳材料,1995年,1卷,6页
  • 3张跃,材料科学进展,1992年,4卷,357页
  • 4毛起--,J Wuhan Univ Technol,1996年,11卷,3期,41页
  • 5Chen Puwei,Smart Mater Struct,1993年,2期,22页
  • 6Sheng P,Phys Rev Lett,1978年,40卷,18期,1197页
  • 7Pu-Woei Chen, D.D.L. Carbon-fiber-reinforced concrete as an intrinsically smart concrete for damage assessment during dynamic loading.J. American Ceramic Society, 1995, 78(3): 816 - 818.
  • 8X. Fu, D. D. L. Chung, Self-monitoring of fatigue damage in carbon fiber reinforced cement. Cement and Concrete Research, 1996, 26(1):15-20.
  • 9X. Fu, W. Lu, D.D.L. Chung, Effect of curing age on the self-monitoring behavior of carbon fiber reinforced mortar, Cement and Concrete Research, 1997, 27(9), 1313 - 1318.
  • 10X. Fu, E. Ma, D.D.L. Chung. Improving the strain-sensing ability of carbon fiber-reinforced cement by ozone treatment of the fibers. Cement and Concrete Research, 1998, 28(2): 183 - 187.

共引文献101