摘要
介绍氢回收系统中空纤维膜由于入膜气中带液,导致一级膜损坏的情况。对事故的原因进行分析并处理,还提出了防范措施。
The paper introduces hollow fiber membrane because of containing liquid in in-let gas to membrane in hydrogen recovery system,resulting in the first membrane damaged. And it analyzes causes of the accident and deals with it,it proposes preventive measures.
出处
《氮肥技术》
2015年第5期39-40,共2页
Nitrogenous Fertilizer Technology
关键词
一级膜
事故
原因
处理
the first membrane
accident
causes
treatment