根据国家相关规范要求,介绍了燃气锅炉房火灾自动报警系统设置要求,结合某锅炉房实际工程,分析了燃气锅炉房火灾报警装置设计和可燃气体探测报警系统设计,阐述了报警装置的选择,可为电气设计人员提供参考。
According to relevant national specifications,the setting requirements of automatic fire alarming system for gas-fired boiler room were introduced.Combining by an actural gas-fired boiler room project,the device design,combustible gas detection and alarm system design of automatic fire alarming system for gas-fired boiler room were anayzed.The choice of alarm device was expounded.It can provide references for electrical desigers.
作者
侯贺
HOU he(China Southwest Architectural Design Research Institute Co.,Ltd.,Chengdu 610042,China)
出处
《现代建筑电气》
2019年第8期27-30,46,共5页
Modern Architecture Electric
关键词
燃气锅炉房
火灾自动报警系统
可燃气体探测报警系统
爆炸危险场所
gas-fired boiler room
automatic fire alarming system
combustible gas detection and alarm system
hazardous area