UFLC-MS/MS测定人血浆中度洛西汀浓度及临床血药浓度 被引量:6

Duloxetine Concentration Determination in Human Plasma with UFLC-MS/MS and Applied for Therapeutic Drug Monitoring
原文传递
导出
摘要 目的建立超快速液相-串联质谱法(UFLC-MS/MS)测定人血浆中度洛西汀血药浓度,并应用该方法进行血药浓度监测。方法以格列苯脲为内标,采用蛋白沉淀前处理方法,使用Phenomenex Synergi Hydro-RP色谱柱(2.00 mm×50 mm,0.004mm),以0.1%甲酸-乙腈和0.1%甲酸-水溶液为流动相,流速0.6mL·min^(-1)进行梯度洗脱。质谱采用电喷雾离子源(ESI),以多反应监测(MRM)扫描模式,在正离子电离模式下进行测定,度洛西汀和格列苯脲的定量分析离子对分别为m/z298.197/154.200和m/z494.200/369.100。结果血浆中无干扰测定的内源性物质,线性范围为5~200 ng·mL^(-1),r=0.999 3,相对回收率为93.64%~105.3%,高、中、低日内精密度(RSD)<10.0%,日间精密度(RSD)<8.2%,提取回收率、基质效应、稳定性均通过方法学验证。42例患者度洛西汀血药浓度水平受日剂量影响,年龄对度洛西汀血药浓度影响较大,性别对其血药浓度无影响。结论该方法简单快速、准确、灵敏度高,适用于度洛西汀的临床治疗药物浓度监测。度洛西汀体内血药浓度个体差异较大,受药动学特点、生理因素(年龄)影响,因此需规律监测血药浓度,并实施个体化用药,以提高临床疗效,减少不良反应。 OBJECTIVE To establish an ultra-high performance liquid chromatography method for the determination of duloxetine in human plasma and to apply this method for therapeutic drug monitoring(TDM)of duloxetine.METHODS The LC-MS/MS was applied for determination of duloxetine plasma concentration with glibenclamide as internal standard and Phenomenex Synergi Hydro-RP(2.00 mm×50 mm,0.004 mm)as column.The mobile phases were consisted of 0.1%formic acid in acetonitrile and 0.1%formic acid in water and were pumped at a flow rate of 0.6 mL×min-1.Quantitative analysis was conducted in the multiple reaction monitoring modes with product ion transitions of m/z 298.197/154.200 and m/z494.200/369.100 for duloxetine and internal standard,respectively.RESULTS Chromatograms showed no endogenous interfereing peaks in the respective blank human plasma samples.The calibration was linear in the concentration range with5-200 ng·mL-1(r=0.999 3)and the relative recoveries were at 93.64%-105.3%.Inter-day and intra-day RSD were less than10.0%and 8.2%,respectively.Both the extraction recovery matrix effect and the stability were validated for duloxetine in human plasma.The plasma concentration of duloxetine levels were significantly affected by age(P<0.05),but not by genter.CONCLUSION This method is simple,rapid,specific and precise for the determination of duloxetine in human plasma and it could be widely used for TDM.The plasma concentrations of duloxetine were variability,especially significantly affected by age.Rotine TDM of duloxetine may improve the treatment response.
作者 王晶晶 姚勤 黄桦 何瑾 周琼 李骞 杨成金 张峻 WANG Jingjing;YAO qin;HUANG Hua;HE Jin;ZHOU Qiong;LI Qian;YANG Chengjin;ZHANG Jun(Department of Clinical Pharmacy,First Affiliated Hospital of Kunming Medical University,Kunming 650003,China;Yunnan Baiyao Co.,Ltd.,Kunming 650502,China)
出处 《中国现代应用药学》 CAS CSCD 北大核心 2019年第8期951-955,共5页 Chinese Journal of Modern Applied Pharmacy
基金 云南省教育厅科学研究基金项目资助(2017zDX166) 云南省高层次卫生计生技术人才培养专项经费资助(L-201614 H-2017020 H-2017051 H-2017052)
关键词 度洛西汀 超快速液相-串联质谱法 治疗药物监测 血药浓度 duloxetine UFLC-MS/MS therapeutic drug monitoring plasma concentration
  • 相关文献

参考文献9

二级参考文献160

共引文献79

同被引文献60

引证文献6

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部