摘要
针对山西铝厂 160t/h锅炉在实际运行中膨胀异常的问题 ,对不同的施工方法下 ,水冷壁膨胀量是否正常这一问题进行分析 ,找出了水冷壁膨胀异常的原因 。
According to the abnormal expansion issue existed in 160t/h boiler and the normal expansion capacity of water wall under various construction conditions analysis is carried out. the causing reasons are find out and corresponding measures are proposed.
出处
《山西建筑》
2004年第1期53-54,共2页
Shanxi Architecture