期刊文献+

Biocorrosion properties of Ti–3Cu alloy in F ion-containing solution and acidic solution and biocompatibility 被引量:4

Biocorrosion properties of Ti–3Cu alloy in F ion-containing solution and acidic solution and biocompatibility
原文传递
导出
摘要 Ti–3Cu alloy has shown low melting point and strong antibacterial properties against S.aureus and E.coli and thus has potential application as dental materials and orthopedic application.In this paper, the corrosion properties of Ti–3Cu alloy in five kinds of simulated solutions were investigated in comparison with cp-Ti(commercially pure titanium) by electrochemical technology and immersion experiment.Electrochemical results have demonstrated that Ti–3Cu alloy exhibited much nobler corrosion potential, lower corrosion current density and high corrosion resistance than cp-Ti in all solutions, especially in saliva-pH6.8+0.2 F and saliva-pH3.5, indicating that Ti–3Cu alloy has much better anticorrosion properties than cpTi.Immersion results have shown that Ti ion and Cu ion were released from Ti–3Cu, especially in saliva-pH6.8+0.2 F and saliva-pH3.5 solutions.Both electrochemical data and immersion results have indicated that high corrosion rate and high metal ion release rate were detected in F ion-containing solution and low-pH solution, displaying that F^- and low pH had much strong aggressive attack to cp-Ti and Ti–3Cu alloy.The corroded surface morphology was observed by scanning electron microscopy(SEM), and the roughness was tested in the end.The good corrosion resistance of antibacterial Ti–3Cu alloy suggests its great potential as a long-term biomedical application. Ti–3Cu alloy has shown low melting point and strong antibacterial properties against S.aureus and E.coli and thus has potential application as dental materials and orthopedic application.In this paper, the corrosion properties of Ti–3Cu alloy in five kinds of simulated solutions were investigated in comparison with cp-Ti(commercially pure titanium) by electrochemical technology and immersion experiment.Electrochemical results have demonstrated that Ti–3Cu alloy exhibited much nobler corrosion potential, lower corrosion current density and high corrosion resistance than cp-Ti in all solutions, especially in saliva-pH6.8+0.2 F and saliva-pH3.5, indicating that Ti–3Cu alloy has much better anticorrosion properties than cpTi.Immersion results have shown that Ti ion and Cu ion were released from Ti–3Cu, especially in saliva-pH6.8+0.2 F and saliva-pH3.5 solutions.Both electrochemical data and immersion results have indicated that high corrosion rate and high metal ion release rate were detected in F ion-containing solution and low-pH solution, displaying that F^- and low pH had much strong aggressive attack to cp-Ti and Ti–3Cu alloy.The corroded surface morphology was observed by scanning electron microscopy(SEM), and the roughness was tested in the end.The good corrosion resistance of antibacterial Ti–3Cu alloy suggests its great potential as a long-term biomedical application.
出处 《Rare Metals》 SCIE EI CAS CSCD 2019年第6期503-511,共9页 稀有金属(英文版)
基金 financially supported by the National Natural Science Foundation of China (Nos.81071262 and 31271024) the Funding from Northeastern University, China (Nos.N141008001 and LZ2014018) Beijing Municipal Natural Science Foundation (No.7161001)
关键词 TI alloy Corrosion resistance Ion release Antibacterial material Ti alloy Corrosion resistance Ion release Antibacterial material
  • 相关文献

参考文献3

二级参考文献13

  • 1张彬,林艳,唐晓宁,许寅华,谢刚.Mechanism of antibacterial activity of silver and praseodymium-loaded white carbon black[J].Journal of Rare Earths,2010,28(S1):442-445. 被引量:10
  • 2廖娟,徐薇,莫安春.纯钛种植体表面抗菌改性的研究进展[J].国际口腔医学杂志,2007,34(3):213-215. 被引量:11
  • 3ZhaoL,Wang H,Huo K, et al. Antibacterial nano - structured ti-tanic coating incorporated with silver nanoparticles [ J ]. Biomaterials,2011,32(24) : 5706-5716.
  • 4Zhao L,Chu PK,Zhang Y,et al. Antibacterial coatings on tita - ni-um implants[ J] . J Biomed Mater Res B Appl Biomater,2009, 91(1): 470-480.
  • 5Necula BS, Apachitei I,Tichelaar FD, et al. An electron microscop-ical study on the growth of Ti02 - Ag antibacterial coatings onTi6A17Nb biomedical alloy[ J]. Acta Biomater, 2011,7(6) : 2751-2757.
  • 6Shibata Y,Suzuki D,Omori S,et al. The characteristics of in itrobi-ological activity of titanium surfaces anodically oxidized in chloridesolutions[ J]. Biomaterials, 2010, 31(33) : 8546 -8555.
  • 7Whiteside P, Matykina E, Gough JE, et al. In vitro evaluation ofcell proliferation and collagen synthesis on titanium following plasmaelectrolytic oxidation[ J] J Biomed Mater Res A,2010, 94( 1 ) : 38 -46.
  • 8J Liu,F Li,C Liu,et al. Effect of Cu content on the antibacterial ac-tivity of titanium - copper sintered alloys[ J]. Materials Science andEngineering,2014,35 (2014) 392-400.
  • 9International Standard ISO 10993 -12 Biological evaluation of medi-cal devices Part 12: sample preparation and reference materials,(2007).
  • 10李慕勤,王健平,赵莉.天然高分子/羟基磷灰石支架材料对成骨细胞增殖的影响[J].黑龙江医药科学,2008,31(5):1-2. 被引量:8