摘要
给出了水系统次不利环路概念。介绍了根据最大流量和次不利环路阻力损失选择水泵的方法。理论和实例分析证明 ,该方法比传统的根据最大流量和最不利环路阻力损失选择水泵的方法节能。
Puts forwards the concept of the second worst loop of water systems. Presents the way of selecting pumps according to the maximum flow rate and resistance loss of the second worst loop. A theoretic and example analysis shows that this way energy consumption is less than that of selecting pumps based on the maximum flow rate and the worst loop.
出处
《暖通空调》
北大核心
2003年第6期75-77,共3页
Heating Ventilating & Air Conditioning
关键词
水泵
流量
节能
水力平衡
阻力损失
second worst loop, pump, flow rate, energy saving