摘要
针对FNT型冷却塔结构强度的设计问题进行了理论计算,根据材料力学理论方法,得到了冷却塔各部件的强度值,结果表明:冷却塔各部件的强度均足够,该计算方法对冷却塔的结构设计是有参考价值的.
The design about intensity of the structure in FNT genre refrigerant tower is calculated theoretically. According to material mechanics theory, getting the results of parts of refrigerant tower. It has been shown that the intensity of parts of refrigerant tower is sufficient. What's more, the method of calculation has main referenced value for the design of refrigerant tower.
出处
《北京工商大学学报(自然科学版)》
CAS
2003年第4期46-48,共3页
Journal of Beijing Technology and Business University:Natural Science Edition