期刊文献+

Resistance Measurements and Interpretations Relating to Flashover of Artificially Contaminated Ceramic Insulator Strings

Resistance Measurements and Interpretations Relating to Flashover ofArtificially Contaminated Ceramic Insulator Strings
下载PDF
导出
摘要 The flashover of insulator strings occurring at normal working voltages undercontaminated/polluted conditions, obviously deserves serious consideration. Though much researchhas been gone into pollution-induced flashover phenomena but grey areas still exist in ourknowledge. In the present experimental study the breakdown (flashover) voltages across gaps oninsulator top surfaces and gaps between sheds (on the underside of an insulator), also the flashoverstudies on a single unit and a 3-unit insulator strings were carried out. An attempt has been madeto correlate the values obtained for all the cases. From the present investigation it was found thatresistance measurement of individual units of a polluted 3-unit string before and after flashoverindicates that strongly differing resistances could be the cause of flashover of ceramic discinsulator strings. The flashover of insulator strings occurring at normal working voltages undercontaminated/polluted conditions, obviously deserves serious consideration. Though much researchhas been gone into pollution-induced flashover phenomena but grey areas still exist in ourknowledge. In the present experimental study the breakdown (flashover) voltages across gaps oninsulator top surfaces and gaps between sheds (on the underside of an insulator), also the flashoverstudies on a single unit and a 3-unit insulator strings were carried out. An attempt has been madeto correlate the values obtained for all the cases. From the present investigation it was found thatresistance measurement of individual units of a polluted 3-unit string before and after flashoverindicates that strongly differing resistances could be the cause of flashover of ceramic discinsulator strings.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2003年第6期2093-2100,共8页 等离子体科学和技术(英文版)
关键词 artificially contaminated/polluted insulator strings resistancemeasurements insulator flashover breakdown voltages ceramic insulators artificially contaminated/polluted insulator strings resistancemeasurements insulator flashover breakdown voltages ceramic insulators
  • 相关文献

参考文献2

二级参考文献18

  • 1Holte K C, et al. Application of Insulators in a contaminated environment. IEEE Trans on Power Apparatus and Systems, Vol. PAS-98, 1979, 5:1676 ~ 1695.
  • 2Cigre working group 33-04-01. Polluted Insulators: A review of current knowledge. 1999.
  • 3Torbjorn Sorqvist and Antonious Vlastos, Performance and Ageing of Polymeric Insulators. IEEE Trans on Power Delivery, 1997, 12(4): 1657 ~ 1665.
  • 4Fernando M A R M, Gubanski S M. Leakage current patterns on contaminated polymeric surfaces.IEEE Trans. on Dielectrics and Electrical Insulation, 1999, 6:688 ~ 694.
  • 5Suda T. Frequency characteristics of leakage current waveforms of an artificially polluted suspension Insulator. IEEE Trans. on Dielectrics and Electrical Insulation, 2001, 8:705 ~ 709.
  • 6Devendranath D, et al. Leakage current and charge in RTV coated insulators under pollution conditions. IEEE Trans. on Dielectrics and Electrical Insulation, 2002, 9(2):294~ 299.
  • 7Felix Amarh, Karady G G, Raji Soundarajan.Linear stochastic analysis of polluted insulator leakage current. IEEE Trans. on power delivery,2002, 17(4): 1063 ~ 1069.
  • 8IEC Publication 507-1991, Artificial pollution tests on high voltage insulators to be used on acsystems, 1991.
  • 9IEC Report Publication-815-1986, Guide for the selection of insulators in respect of polluted conditions, 1986.
  • 10Subba Reddy B. A Basic Experimental Approach to pollution induced flashover phenomena across ceramic insulators. M Sc (Engg) Thesis, Dept of High Voltage Engg, Indian Institute of Science,Bangalore (India), Jan 2003.

共引文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部