摘要
国内目前工矿企业吊车供电采用最多的方式是安全式滑触线供电,根据设计及项目施工服务经验,结合金川集团铜电解项目50kt/a规模铜电解车间吊车安全滑触线选型、安装实例,介绍了安全滑触线的设计选型和安装时应注意的一些问题。
ion:The most methods have adopted currently in the domestic industry and mineral enterprises and used safety trolley line for power supply. According to many years of design and project construction service experience,the author combines the copper electrolysis item of Jinchuan group with on the scale of 50kt/a copper electrolysis plant on choosing safety trolley line and installing example. Some considerable problems in the field of choosing safety trolley line and installing are introduced in this paper.
出处
《江西电力》
2003年第6期41-43,共3页
Jiangxi Electric Power
关键词
吊车
供电安全
滑触线
设计
选型
起重机
供电线路
导体材料
crane
security
slide wire
collector
compensate wire
calculate electricity
pcak current