口腔数字成像系统在根管测量与充填中的应用
The Application of Oral Digital Imaging System in Root Canal Measurement and Filing
出处
《上海口腔医学》
CAS
CSCD
2003年第6期413-413,421,共2页
Shanghai Journal of Stomatology
参考文献3
-
1樊明文.牙髓病学[M].第4版,北京:人民卫生出版社,2000,254-255.
-
2刘丹,石四箴.Digora数字化X线摄影系统在口腔科的应用[J].牙体牙髓牙周病学杂志,2000,10(1):49-52. 被引量:15
-
3洪亮,谭红,胡涛.应用直接数字成像技术诊断口腔内科常见疾病的可行性研究[J].牙体牙髓牙周病学杂志,2000,10(5):273-275. 被引量:12
二级参考文献30
-
1[1] Versteeg KH,Sanderink GC, Velders XL, et al. In vivo study of approximal caries depth on storage phosphor plate images compared with dental X-ray film. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 1997,84(2):210
-
2[2] Moystad A, Svanaes DB, Risnes S, et al. Detection of approximal caries with a storage phosphor system:a comparison of enhanced digital images with dental X-ray film. Dentomaxillofac Radiol, 1996,25:202
-
3[3] Svanaes DB, Moystad A, Risnes S, et al. Intraoral storage phosphor radiography for approximal caries detection and effect of image magnification. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 1996,82(1):94
-
4[4] Wenzel A, Gotfredsen E, Borg E, et al. Impact of lossy image compression on accuracy of caries detecion in digital images taken with a storage phosphor system. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 1996,81(3):351
-
5[5] Wenzel A, Borg E, Hintze H, et al. Accuracy of caries diagnosis in digital images from charge-coupled device and storage phosphor systems:an in vitro study. Dentomaxillofac Radiol, 1995,24:250
-
6[6] Borg E, Grondahl HG. A comparison of image quality in filim, charge-coupled device and storage phosphor systems. Dentomaxillofac Radiol, 1996,25:82
-
7[7] Nielsen LL, Hoernoe M, Wenzel A. Radiographic detection of cavitation in approximal surfaces of primary teeth using a digital storage phosphor system and conventional film, and the relationship between cavitation and radiographic lesion depth: an in vitro study. Int J paediatr Dent, 1996,6(3):167
-
8[8] Gotfredsen E, Wenzel A, Grondahl HG. Observeers' use of image enhancement in assessing caries in radiographs taken by four intraoral digital systems. Dentomaxillofac Radiol, 1996,25(1):34
-
9[9] Okano T, Wiebe JD, Webber RL, et al. Effective exposure level and diagnostic performance in endodontic radiography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod,1983,55:527
-
10[10] Borg E, Grondahl HG. Endodontic measurements in digital radiographs acquired by a photostimulable, storage phosphor system. Endod Dent Traumatol, 1996,12(1):20
共引文献24
-
1沙海亮,白玉兴.牙根吸收的影像学进展[J].口腔正畸学,2004,11(3):140-143. 被引量:1
-
2高永波,吴熙凤,王云芬,杨明玉.口腔数字成像系统X线传感器定位器的研制和临床应用[J].口腔材料器械杂志,2004,13(4):188-190. 被引量:9
-
3姚莉莉,汪涌,赵兵.电测法结合X线直视摄影术在根管长度测量中的应用[J].中国临床保健杂志,2005,8(3):219-220. 被引量:1
-
4张芳,王非,晋江丰,臧满丽.根尖片数字化X线摄影和传统X线摄影在根管治疗中应用比较[J].中日友好医院学报,2005,19(5):272-274. 被引量:7
-
5李英炜.手感法结合X线直视摄影术测量根管工作长度的评价[J].内蒙古医学院学报,2007,29(3):211-212.
-
6李英炜,刘福勇,刘冉美,程凤峡.手感法与X直线直视摄影术相结合测量根管工作长度的体外研究[J].现代口腔医学杂志,2007,21(6):625-626.
-
7曾东林,温奕雄,崔敏毅,涂之平.数字化牙片图像质量的临床分析[J].牙体牙髓牙周病学杂志,2008,18(1):42-45. 被引量:8
-
8李英炜,刘福勇,李云华.根管内预备中工作长度的临床测定及分析[J].内蒙古医学院学报,2007,29(6):439-441.
-
9李英炜,赵丽霞,关晶,刘福勇.两种根管工作长度测量法准确性的临床评价[J].现代口腔医学杂志,2008,22(4):440-440. 被引量:1
-
10王凤琼,黄文,覃燕玲,秦晓丹,蒋谊芳,涂晓宁,常晓杰.口腔直接数字成像图像质量的评价[J].上海口腔医学,2008,17(5):552-554. 被引量:1
-
1孙墅,郑苍尚.根管测量两次法在根管治疗中的应用评价[J].口腔医学研究,2014,30(4):368-369. 被引量:1
-
2王靖.牙髓活力对根管长度测量仪准确性影响的临床研究[J].重庆医学,2010,39(10):1233-1234. 被引量:3
-
3马良,田慧颖,姚军,冯超,晋江丰,马丹丹.应用口腔数字成像系统诊断牙齿及牙周疾病的研究[J].中国医学影像学杂志,1999,7(2):99-101.
-
4邵立强,原凤霞.手测法测定磨牙根管长度的临床分析[J].临床口腔医学杂志,2002,18(2):104-105.
-
5高永波,吴熙凤.口腔数字成像系统在牙周病疗效观察中的评价[J].临床口腔医学杂志,2004,20(3):161-162. 被引量:5
-
6郑红,黄永丽.两种方法测量根管工作长度的比较研究[J].河南大学学报(医学版),2006,25(1):37-38. 被引量:1
-
7邓淑丽,应红.根管长度测量仪准确性的临床评价[J].浙江医学,2003,25(8):494-495.
-
8吕健,曹奕.根管测量仪测量老年人根尖周炎磨牙根管工作长度的准确性[J].齐鲁医学杂志,2006,21(4):343-344. 被引量:2
-
9宋卫健.根管长度测量仪测定前牙根管工作长度准确性的评价[J].口腔医学,2007,27(1):41-42. 被引量:4
-
10阳冬青,朱建成,张泳,邱睿,刘建东.超声根管预备联合热牙胶垂直加压充填对侧支根管充填的效果[J].现代医药卫生,2010,26(15):2278-2280.