摘要 现场试验了一种油溶性缓蚀荆和两种水溶性缓蚀剂.结果显示:在不注中和荆(氨水)的条件下,注入12~13μg/g IMC-石大1号油溶性缓蚀剂能将二价铁离子浓度降低到2mg/L左右.注入15~20μg/g水溶性缓蚀剂才能将的二价铁离子浓度降低到3~33mg/L.IMC-石大2号油溶性缓蚀剂的防腐蚀效果优于水溶性缓蚀剂. One oil soluble corrosion inhibitor and 2 water soluble inhibitors have been tested in the commercial units. The results show that the addition of IMC - Shida NO. 2 oil soluble corrosion inhibitor at 12 ~ 13 ppm can reduce iron ion to about 2 mg/L without injection of neutralizing agent (ammonia water), while 15-20 ppm water soluble corrosion inhibitor is required to reduce the iron ion to 3 ~ 33 mg/L in the condensing system of the atmospheric distillation unit. IMC - Shida NO. 2 oil soluble inhibitor is obviously superior over water soluble inhibitor in performance.
出处 《石油化工腐蚀与防护》 CAS 2003年第6期24-27,共4页 Corrosion & Protection In Petrochemical Industry
关键词 炼油厂 缓蚀剂 性能评价 常减压蒸馏装置 蒸馏塔 冷凝系统 腐蚀 corrosion inhibitor, distillation tower, condensing system commercial application evaluation