摘要
对原有NHD脱碳流程进行改进 ,将低压闪蒸槽移至气提塔上部 ,运用柏努利方程计算了NHD脱碳系统中富液从高压闪蒸槽至低压闪蒸槽的压力降 ,从而确定了将高压闪蒸槽的位移高度。取消原流程中的富液泵 ,不仅减少了投资 ,而且节省了操作费用。
An improvement is made on the original NHD CO_2 removal process by moving the low-pressure flash tank to the top of the stripper and using the Bernoulli equation to calculate the pressure drop of the rich solution from the high-pressure flash tank to the low-pressure flash tank in the NHD CO_2 removal system, and thus the displacement height of the high-pressure flash tank is ascertained. The elimination of the rich solution pump in the original process not only ?reduces the investment costbut also lowers the operating cost.
出处
《化肥工业》
CAS
2003年第6期51-52,共2页
Chemical Fertilizer Industry