3.0T MRI肩关节磁共振螺旋桨采集技术与常规扫描技术的诊断价值 被引量:6

下载PDF
导出
摘要 目的对比3.0T MRI肩关节磁共振螺旋桨采集(PROPELLER)技术与常规扫描技术的诊断价值。方法选取2016年9月至2018年5月进行肩关节MRI扫描的患者80例作为研究对象,均采用常规扫描技术和PROPELLER技术为患者进行扫描,并比较扫描结果。结果 PROPELLER技术扫描血管搏动伪影、运动伪影、呼吸伪影、冈上肌边缘锐利度、总体图像质量均优于常规扫描技术,差异有统计学意义(P<0.05)。PROPELLER技术扫描图片时间短于常规扫描技术,采集图片次数少于常规扫描技术,差异有统计学意义(P<0.05)。结论相比于常规扫描技术,PROPELLER技术可获得更为优质的图像质量,降低伪影,并可有效缩短扫描图片时间,减少采集图片次数。
作者 刘咏梅
出处 《医疗装备》 2019年第3期37-38,共2页 Medical Equipment
  • 相关文献

参考文献5

二级参考文献23

  • 1Pipe JG. Motion correction with PROPELLER MRI. Application to head motion and free -breathing cardiac imaging [ J ]. Magn Reson Med, 1999,42:963 - 969.
  • 2Pipe J G.Motion correction with PROPELLER MRI:application to head motion and free-breathing cardiac imaging[J].Magn Reson Med,1999,42(5):963-969.
  • 3Alibek S,Adamietz B,Cavallaro A,et al.Contrast-enhanced T1-weighted fluid-attenuated inversion recovery BLADE magnetic resonance imaging of the brain:an alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient?[J].Acad Radiol,2008,15(8):986-995.
  • 4Aksoy M,Skare S,Holdsworth S,et al.Effects of motion and b-matrix correction for high resolution DTI with short-axis PROPELLER-EPI[J].NMR Biomed,2010,23(7):794-802.
  • 5Lummel N,Schoepf V,Burke M,et al.3D fluid-attenuated inversion recovery imaging:reduced CSF artifacts and enhanced sensitivity and specificity for subarachnoid hemorrhage[J].Am J Neuroradiol,2011,32(11):2054-2060.
  • 6Dietrich T J,Ulbrich E J,Zanetti M,et al.PROPELLER technique to improve image quality of MRI of the shoulder[J].Am J Roentgenol,2011,197(6):1093-1100.
  • 7Nyberg E,Sandhu G S,Jesberger J,et al.Comparison of brain MR images at 1.5T using BLADE and rectilinear techniques for patients who move during data acquisition[J].Am J Neuroradiol,2012,33(1):77-82.
  • 8Lane B F,Vandermeer F Q,Oz R C,et al.Comparison of sagittal T2-weighted BLADE and fast spin-echo MRI of the female pelvis for motion artifact and lesion detection[J].Am J Roentgenol,2011,197(2):307-313.
  • 9Huang T Y,Tseng Y S,Tang Y W,et al.Optimization of PROPELLER reconstruction for free-breathing T1-weighted cardiac imaging[J].Med Phys,2012,39(8):4896-4902.
  • 10Lane BF, Vandermeer FQ, Oz RC, et al.Comparison of sagital T2- weighted BLADE and fast spin-echo MRI of the female pelvis for mo- tion artifact and lesion detection[J].Am J Roentgenol,2011,197(2): 307-313.

共引文献33

同被引文献54

引证文献6

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部