2011年济宁市城区公共场所集中空调通风系统卫生状况调查 被引量:2

Survey on Hygienic Status of Centralized Air Ventilation System in Public Places of Urban Area,Jining City,2011
原文传递
导出
摘要 [目的]了解济宁市公共场所集中空调通风系统的卫生状况,为改善公共场所的卫生状况、加强公共场所卫生监管工作提供决策依据。[方法]2011年5~7月,在济宁市城区抽取28家使用集中空调通风系统的机关、公共场所进行现场卫生学调查与积尘中微生物检测。[结果]调查15家公共场所单位,均建立健全了卫生组织与管理制度;集中空调新风口位置符合卫生要求的占66.67%,在空调的风管系统安装了供监督检测、清洗消毒用窗口的占60.00%,安装了空气净化消毒装置的占20.00%;空调系统冷凝水能够集中排放,排水管道无堵塞的占86.67%;空调房间内的送、回风口能够经常性清洗,保持风口表面无积尘霉斑的占26.67%。检测管道积尘172份,积尘量均值69.43g/m2,合格率为69.19%;细菌总数均值为2 249CFU/cm2,合格率为43.60%;真菌总数均值为3 494CFU/cm2,合格率为27.91%;军团菌均未检出。不同单位细菌总数、真菌总数的差异均有统计学意义(P<0.01)。[结论]济宁市城区公共场所集中空调通风系统的卫生状况较差。 [Objective]To understand sanitary condition of the centralized air ventilation system in public places,so as to provide basis for strengthening health supervision.[Methods]By random sampling,28 samples of central air conditioning ventilation system authority and public places were collected for hygienic survey and testing dust microorganism during May-July,2011.[Results]In 15 public places,the health organization and management system were established.The central air conditioning fresh air inlet position meeting the hygienic requirements accounted for 66.67%,the system installed with window for supervision and inspection,cleaning and disinfection n the air-conditioning duct accounted for 60.00%,installed with air purification and disinfection equipment accounted for 20.00%;the condensed water air conditioning system to concentrate discharge,drainage pipeline without plug accounted for 86.67%;sending,returning air regular cleaning air conditioning room,keep the tuyere surface no dust mildew accounted for 26.67%.In detection of 172 samples of pipeline dust,the mean dust value was 69.43 g/m2,the qualified rate was 69.19%;the total count of bacteria average is 2 249 CFU'cm2,the qualified rate is 43.60%;total fungi average was 3 494 C FU/cm2,the qualified rate was 27.91%;No Legionella was detected(P<0.01).[Conclusion]The sanitary condition of the centralized air ventilation system is worse in public places of urban area in Jining city.
出处 《预防医学论坛》 2013年第2期101-102,共2页 Preventive Medicine Tribune
关键词 集中空调 通风系统 微生物污染 Central air conditioning Ventilation system Microbial contamination
  • 相关文献

参考文献4

二级参考文献17

  • 1杨翠婵,陆也民.空调办公室环境质量与人群健康状况的调查[J].广东卫生防疫,2001,27(1):58-59. 被引量:8
  • 2梁惠宁.空调客房与非空调客房的卫生学调查[J].环境与健康杂志,1996,13(3):127-127.
  • 3Backman-H, Haghighat-F. Indoor air quality and ocular discomfort[J] .J AM optom Assoc, 1999, 70(5) :309 - 316.
  • 4Nordstrom K, Norback D, Akselsson R. Effect of air humidification on the sick building syndrome and perceived indoor air quality in hospitals: A four month longitudinal study [J ]. Occup Environ Med, 1994, 51(10) :683 - 688.
  • 5Keller DW.Community Outbreak of Legionnairesp disease:an investigation confirmingthe potential for coolingtowers totransmit legionella species[J].Clin Infect Dis,1996,22:2572261.
  • 6Keller BW,Hajjeh R,Maria AD,et al.Community outbreak of Legionnaires'disease:An investigation confirming the potential for cooling tower to transmit Legionella species[J].Clin Infect Dis,1996,22:2572261.
  • 7Dondero TJ,Rendorff RC,Mallison GF,et al.An outbreak of Legionnaires'disease asociateel with a contaminated air conditioning cooling tower[J].N Engl J Med,1980,302:3652370.
  • 8刘建军.深圳市1998 1999年流行性感冒监测[J].中华流行病学杂志,2001,22(2):158-159.
  • 9环境与健康杂志编辑部.世界卫生组织公布香港淘大花园SARS传播的环境卫生报告.环境与健康杂志,2003,20(4):245-245.
  • 10夏正英,佘德宏,赵霞.扬州市新装饰开业公共场所甲醛污染状况[J].环境与健康杂志,2000,17(5):287-289. 被引量:15

共引文献76

同被引文献20

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部