摘要 目的:观察分析低浓度对比剂在冠状动脉CTA检查中的临床应用。方法:随机选取2016年5月—2017年5月我院收治的疑似冠状动脉且需进行CTA检查患者58例进行对比实验,给予对照组常规扫描,实验组则采取双低扫描。对比两组CT值、SNR、CNR和辐射剂量。结果:实验组患者CT值与辐射剂量各项参数指标均优于对照组(P<0.05)。结论:低浓度对比剂可有效减少高碘注入量造成的肾脏代谢负荷,提高CTA检测安全性。
作者 徐鹏飞
出处 《影像研究与医学应用》 2018年第2期57-58,共2页 Journal of Imaging Research and Medical Applications
  • 相关文献

参考文献2

二级参考文献26

  • 1陈静,范崇济.造影剂肾病的危险因素及防治研究进展[J].医学综述,2006,12(3):181-184. 被引量:18
  • 2B. Wintersperger,T. Jakobs,P. Herzog,S. Schaller,K. Nikolaou,C. Suess,C. Weber,M. Reiser,C. Becker.Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose[J]. European Radiology . 2005 (2)
  • 3Michael Lell,Mohamed Marwan,Tiziano Schepis,Tobias Pflederer,Katharina Anders,Thomas Flohr,Thomas Allmendinger,Willi Kalender,Dirk Ertel,Carsten Thierfelder,Axel Kuettner,Dieter Ropers,Werner G. Daniel,Stephan Achenbach.Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience[J]. European Radiology . 2009 (11)
  • 4Dirk Ertel,Michael M. Lell,Frank Harig,Thomas Flohr,Bernhard Schmidt,Willi A. Kalender.Cardiac spiral dual-source CT with high pitch: a feasibility study[J]. European Radiology . 2009 (10)
  • 5Jean-Fran?ois Paul,Hicham T. Abada.Strategies for reduction of radiation dose in cardiac multislice CT[J]. European Radiology . 2007 (8)
  • 6Sebastian Leschka,Paul Stolzmann,Lotus Desbiolles,Stephan Baumueller,Robert Goetti,Thomas Schertler,Hans Scheffel,Andre Plass,Volkmar Falk,Gudrun Feuchtner,Borut Marincek,Hatem Alkadhi.Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience[J]. European Radiology . 2009 (12)
  • 7Thorsten R. C. Johnson,Konstantin Nikolaou,Bernd J. Wintersperger,Alexander W. Leber,Franz Ziegler,Carsten Rist,Sonja Buhmann,Andreas Knez,Maximilian F. Reiser,Christoph R. Becker.Dual-source CT cardiac imaging: initial experience[J]. European Radiology . 2006 (7)
  • 8J?rg Hausleiter,Tanja Meyer,Martin Hadamitzky,Ester Huber,Maria Zankl,Stefan Martinoff,Adnan Kastrati,Albert Sch?mig.Radiation Dose Estimates From Cardiac Multislice Computed Tomography in Daily Practice: Impact of Different Scanning Protocols on Effective Dose Estimates[J]. Circulation . 2006 (10)
  • 9James P. Earls.How to use a prospective gated technique for cardiac CT[J]. Journal of Cardiovascular Computed Tomography . 2009 (1)
  • 10John Hoe,K.H. Toh.First experience with 320-row multidetector CT coronary angiography scanning with prospective electrocardiogram gating to reduce radiation dose[J]. Journal of Cardiovascular Computed Tomography . 2009 (4)

共引文献11

同被引文献19

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部