摘要 目的:探讨分析冠状动脉CT血管造影检查方法在疑难胸痛患者临床诊断过程中的应用价值。方法:以我院内科收治的65例经由冠状动脉造影检查确诊的疑难胸痛患者作为研究对象,运用西门子SOMATOM Definition双源CT检查设备针对患者实施冠状动脉CT血管造影检查,统计分析患者的冠状动脉血管组织病变检出率指标。结果:对于本组接诊收治的65例疑难胸痛患者而言,有54例患者借由实施冠状动脉CT血管造影检查成功检出冠状动脉血管组织病变,该组患者的冠状动脉血管组织病变检出率指标为83.08%(54/65)。结论:为内科收治的疑难胸痛患者展开冠状动脉血管造影检查处置,能够有效揭示患者的冠状动脉血管组织病变,支持患者获取到科学有效治疗。
出处 《影像研究与医学应用》 2018年第14期98-99,共2页 Journal of Imaging Research and Medical Applications
  • 相关文献

参考文献3

二级参考文献19

  • 1James Thomas Patrick Decourcy Hallinan,Gopinathan Anil.Multi-detector computed tomography in the diagnosis and management of acute aortic syndromes[J].World Journal of Radiology,2014,6(6):355-365. 被引量:11
  • 2俞高龙,李海兵,陆明华,桑奇潜,王翀妙.多层螺旋CT量化冠状动脉钙化的评价[J].心脏杂志,2004,16(4):335-336. 被引量:7
  • 3Coles DR, Smail MA, Negus IS. Comparison of radiation doses from multislice computed tomography coronary angiography and conventionaldiagnostic angiography[J]. Journal of The American College of Cardiology, 2006, (9): 1840-1845.
  • 4Onal E, Y11dlz AE, Galer E, et al. Comparison of image quality and radiation dose between prospectively ECG-triggered and retrospectively ECG-gated CT angiography: Establishing heart rate cut-off values in first-generation dual-source CT[J]. Anatolian Journal of Cardiology, 2015, (7): 5152.
  • 5Chinnaiyan KM, Bilolikar AN, Walsh E, et al. CT dose reduction using prospectively triggered or fast-pitch spiral technique employed in cardiothoracic imaging (the CT dose study) [J]. Journal of Cariovascular Computed Tomography, 2014, 8(3): 205-214.
  • 6KrissaK R, Henzler T, Prechel A, et al. Triple-rule-out dual-source CT angiography of patients with acute chest pain: Dosereduction potential of 100 kVscanning[J]. Uropean Journal of Radiology, 2012, 81 (12): 3691-3696.
  • 7Lee HY, Yoo SM, White CS. Coronary CT angiography in emergency department patients with acute chest pain: Triple rule-out proctocol versus dedicate coronary CT angiography[J]. The International Journal of Cardiovascular Imaging, 2009, 25(3): 319-326.
  • 8Hsieh J, Londt J, Vass M. Step-and-shoot data acquisition and reconstruction for cardiac X ray computed tomography[J]. Medical Physics, 2006, (11): 4236-4248.
  • 9Kligerman SJ, White CS. Image quality and feasibility of an ultralow-dose high-pitch helical triple rule-out computed tomography angiography acquired in the caudocranial direction [J]. Jotrnal of Thoracic Imaging, 2014, 29(1): 50-59.
  • 10朱玲,丁国华.造影剂肾病的发病机制和防治措施[J].世界临床药物,2009,30(8):498-501. 被引量:5