摘要
目的比较采用体层摄影术(CT)、磁共振成像(MRI)图像进行肝体积影像学测量的准确性。方法电子检索Cochrane图书馆、中英文文摘数据库(Medline、Embase、中国生物医学文摘数据库)和期刊全文数据库(Springer、OVID、Sciencedirect、Ebsco、CNKI、万方、维普等),获得利用CT或MRI设备测量全肝体积的中英文文献,根据Cochrane协作网推荐的诊断试验纳入标准筛选文献,根据CT、MRI成像设备分组后进行质量评价,采用基于统计分析软件R的循证医学软件包Meta对纳入文献提取信息进行异质性检验,根据异质性检验结果选择恰当的效应量合并模型进行荟萃分析,分别对纳入的CT和MRI研究进行加权合并及组间比较,合并效应量为影像学测量肝体积和实际肝体积的加权平均差,最后进行敏感性分析和发表性偏倚分析。结果符合纳入标准的17篇文献报道了37项研究,包括351例患者。异质性检验显示CT组(I^2=0%,Q=4.93,P=0.999 8)和MRI组(I^2=0%,Q=0.92,P=1)纳入研究均不具异质性。各组效应量合并采用固定效应模型,CT和MRI组影像学测量肝体积和实际肝体积的加权均数差值分别为21.706 3 ml〔95%可信区间(95%CI)=-8.015 4~51.464 0 ml〕和20.951 8 ml(95%CI=-60.436 0~102.339 5 ml)。两组的影像学测量肝体积和实际肝体积差异均无统计学意义(CT组:Z=1.429 7,P=0.152 8;MRI组:Z=0.504 6,P=0.613 9),两组的汇总结果差异也无统计学意义(Q=0,P=1)。各组汇总结果稳定性好,敏感性分析中逐一排除纳入研究或改变效应量合并模型时,合并结果无明显变化,各纳入研究不存在发表性偏倚,漏斗图各纳入研究对称分布,Deeks线性回归分析不存在显著性(CT组:t=-1.882 0,P=0.075 2;MRI组:t=0.001 5,P=0.998 9)。结论采用CT和MRI图像都可以进行准确的肝体积影像学测量,可以根据患者的具体情况,选择适合患者利益的图像采集方法。
ObjectiveTo compare the accuracy of radiologically estimated liver volume by computed tomography(CT) and magnetic resonance imaging(MRI).Methods Cochrane library, abstract databases〔Medline,Embase,China biology medicine disc(CMBdisc)〕and full text databases(Springer,OVID, Sciencedirect,Ebsco,CNKI,WanFang and VIP) were searched for published papers on whole liver volumetry with CT or MRI modality. Inclusion criteria were based on validity criteria for diagnostic research published by the Cochrane collaboration. Eligible papers were grouped according to imaging modality(CT or MRI)and evaluated for quality before data extraction. With meta-analysis package Meta of R software, the statistical model used to pool the result was selected according to result of heterogeneity test. Group-wise meta-analysis and comparison of included studies of CT and MRI liver volumetry were performed. The pooled result was weighted mean difference between estimated and true liver volume. Finally sensitivity and publish bias analysis was performed.Results17 articles with37 studies including351 patients meet the inclusion criteria. There was no heterogeneity among included studies of each group(CT:I2=0%,Q=4.93,P=0.9998; MRI:I2=0%,Q=0.92,P=1). Fixed effect model was selected for the meta-analysis and the weighted mean difference was21.7063 ml〔95% confidence interval (95%CI)=-8.0154 -51.4640 ml)〕 for the CT group and20.9518 ml(95%CI=-60.4360 -102.3395 ml) for the MRI group. There was no statistically significant difference between the true and radiologically estimated whole liver volume of each group(CT:Z=1.4297,P=0.1528; MRI:Z=0.5046,P=0.6139) and between pooled results of each group(Q=0,P=1). Sensitivity analysis revealed the pooled result of each group was robust which was not affected by excluding any of the included studies or changing the effect model. Funnel plot and publish bias analysis revealed no publish bias(CT:t=-1.8820,P=0.0752;MRI:t=0.0015,P=0.9989). Conclusion Accurate liver volumetry could be performed with CT or MRI images. The imaging acquisition methods should be selected according to the patients' general status with respect to the patients' benefits.
出处
《实用器官移植电子杂志》
2015年第2期102-107,共6页
Practical Journal of Organ Transplantation(Electronic Version)
基金
天津市卫生局科技基金面上项目(2012KY07)
关键词
肝体积
体层摄影术
磁共振成像
META分析
Liver volumetry
Computed tomography
Magnetic resonance imaging
Meta-analysis