期刊文献+

基于PCI总线和DSP芯片的高速实时数据采集处理系统 被引量:3

Data Acquisition and Processing System Based on PCI and DSP
下载PDF
导出
摘要 本文对制约数据采集和处理的两个主要因素 :接口形式和处理器进行了研究。本文具体阐述PCI总线的结构和特点 ,着重论述了PCI与DSP接口、WDM驱动程序设计等问题。 This article introduces mainly the two restriction,interface and processor, on the data acquisition and processing.It sets forth the PCI bus structure and characters,and discusses the interface between the PCI bus and the DSP and also the programming on the WDM driver.
出处 《电子测量与仪器学报》 CSCD 2003年第4期46-52,共7页 Journal of Electronic Measurement and Instrumentation
关键词 数据采集 信号处理 PCI总线 TMS320C671 虚拟设备 DSP Data acquisition,signal processing,PCI bus,TMS320C6711,virtual instrument.
  • 相关文献

参考文献6

  • 1Walter Oney,Programming the Microsoft Windows Driver Model,America,Microsoft Press, 1999.
  • 2Chris Cant,Windows WDM驱动程序开发指南,机械工业出版社,2000.
  • 3ArtBaker JerryLozano.Windows 2000设备驱动程序设计指南[M].北京:机械工业出版社,2001..
  • 4PCI9054 Data Book Version 2.1,PLX 公司,2000.
  • 5李贵山 戚德虎.PCI局部总线开发者指南[M].西安:西安电子科技大学出版社,2000..
  • 6TMS320C6711 Data Sheet, Texas Instruments Incorporated, 2001.

共引文献14

同被引文献31

  • 1刘升.二相步进电机驱动芯片TA8435H及其应用[J].国外电子元器件,2005(3):37-40. 被引量:15
  • 2谢金明.高速数字电路设计与噪声控制技术[M].北京:电子工业出版社,2004.
  • 3MARK I M. EMC and the printed circuit board: Design, theory, and layout made simple[M]. Washington: the Institute of Electrical and Electronics Engineers, 1999, 94-118.
  • 4JONATHAN M, TIMOTHY C, RITTER A, et al. Design of efficient, broadband single-element(20-80mhz) ultrasonic transducers for medical imaging applications[J]. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2003, 50(11): 1548
  • 5VAIRAC P, BALLANDRAS S,. Finite element analysis of the behavior of the scanning micro-deformation microsco[J].IEEE Transactions on Ultrasonics, Ferroelectalcs, and Frequency Control. 2001.48(4): 895-899.
  • 6RUIZ E, FEMAT R, CAMPOS D U. Blood glucose control for type Ⅰ diabetes mellitus: a robust tracking H∞ problem[J]. Control Engineering Practice, 2004, 12: 1179-1195.
  • 7AMARAL C E, WOLF B. Current development in non-invasive glucose monitoring[J]. Medical Engineering & Physics, 2008, 30: 541-549.
  • 8SINGER P, FOSTICK G; SINGER J, et al. Hypoglycemia detection using a non-invasive continuous blood glucose monitoring device in intensive care[J]. Clinical Nutrition Supplements, 2008, 3(1): 6.
  • 9TURA A, MARAN A, PACINI G. Non-invasive glucose monitoring: assessment of technologies and devices according to quantitative criteria[J]. Diabetes Research and Clinical Practice, 2007, 77: 16-40.
  • 10TALATY M S, DEWARRAT F, HUBER D, et al. In vivo life sign application of dielectric spectroscopy and non-invasive glucose monitoring[J]. Journal of Non- Crystalline Solids, 2007, 353:4515-4517.

引证文献3

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部