期刊文献+

紫外分光光度法在混凝处理二沉池出水中的应用 被引量:1

APPLICATION OF ULTRAVIOLET SPECTROPHOTOMETER IN TREATMENT OF SECONDARY EFFLUENT PLANT BY COAGULATION
下载PDF
导出
摘要 本研究根据二沉池出水特点 ,指出了以 2 60nm紫外光 (E2 60 )评价处理二沉池出水的理论依据 ,然后确定了E2 60与COD的关系式为 :E2 60 =0 .0 0 8COD +0 .0 83 ,最后以E2 60为评价指标 ,比较了三种无机混凝剂在不同 pH值条件下对城市二沉池出水的COD去除效果。并确定了最佳混凝剂为三氯化铁 (FC)及混凝条件 :pH 4.5 ,投药量 3 2mg(Fe3 + ) / 1。 Based on the characteristics of effluent from secondary municipal wastewater treatment plant, it was pointed out in the paper that using light absorbance at wavelength 260nm (E260) as indicator was feasible to reflect the water quality. The correlation between E260 and COD was determined as E260=0.008COD+0.083. With E260 as indicator, coagulation using three coagulants to treat the effluent from municipal secondary wastewater was operated. It was shown that Ferrite Chloride was the best coagulant, and pH=4.5 and dosage as 32 mg/l was measured as its optimal operation conditions.
出处 《内蒙古环境保护》 2003年第4期45-47,共3页 Inner Mongolia Environmental Protection
关键词 紫外分光光度法 混凝 二沉池出水 水处理 污水回用 Application of Ultraviolet Spectrophotometer water treatment Coagulation wastewater recycling.