SARS流行期间空调及通风系统的管理 被引量:8

Management of Air Conditioning and Ventilation System during SARS Epidemic Period
下载PDF
导出
摘要 目的 探讨 SARS流行期间空调系统的安全使用方法及如何利用现有的通风系统形成隔离病房内负压 ,有效控制 SARS感染的传播。方法 对北京市 6所 SARS定点收治医院和 3所三级甲等综合医院的空调及排风系统进行实地调研。结果 调查的 9所医院空调系统均可以使用 ;利用现有通风条件可以达到空气流通的效果 ;应用排风系统可以形成隔离病房内负压 ,但不能有效控制空气流向。结论 风机盘管加新风空调系统和分体式房间空调系统可以安全使用 ,隔离病房内通风系统在满足一定条件时可以形成有效负压。 OBJECTIVE To discuss how to use air conditioning safely during SARS epidemic period and how to use existing ventilation system making negative pressure in isolation units, in order to effectively control the infection of SARS. METHODS The air conditioning and ventilation system in six SARS specified hospitals and three general hospitals on the spot was surveyed. RESULTS Air conditioning in nine hospitals that were surveyed all can be used safely. Using existent ventilation system can make air flow; utilizing extract air system can make negative pressure in isolation units, but cannot control airflow effectively. CONCLUSIONS Ducted cooled air plus fan coil units and split room air conditioning can be used safely. Ventilation system in isolation units can produce negative pressure effectively when some special requests achieved.
出处 《中华医院感染学杂志》 CAS CSCD 2003年第11期1067-1069,共3页 Chinese Journal of Nosocomiology
基金 WHO SARS科技合作项目 国家科技部 SARS攻关课题
关键词 SARS 空调 通风系统 管理 感染控制 SARS Air conditioning Ventilation system Management Infection control